CHECKING THE HT COIL

Remove the left side inspection cover (see
REMOVING THE LEFT INSPECTION COVER).
Disconnect the terminal (1).
Unscrew and remove the two screws (2).
Disconnect the spark plug cap (3).
Remove the coil (4).
Use a pocket tester (scale 200 Ω) to measure the
resistance (coil side) between the terminals shown
in the figure (A and B).
If the resistance is incorrect, replace the coil.
Standard value: 0.6 Ω Ω Ω Ω Ω ± 0.1 Ω Ω Ω Ω Ω
Also check the resistance between the high
voltage terminal and the coil casing.
Standard value: 7.4 kΩ Ω Ω Ω Ω
CAUTION
Before measuring, remove the HT cable complete
with spark plug cap.