Minimum Mantel Clearances; Nailing Tab Installation - Napoleon GVF42P Installation And Operating Instructions Manual

Vent free millivolt system
Table of Contents

Advertisement

4.3

MINIMUM MANTEL CLEARANCES

RISK OF FIRE, MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES. FAILURE
TO COMPLY WITH THESE INSTRUCTIONS MAY CAUSE A FIRE OR CAUSE THE APPLIANCE TO
OVERHEAT. ENSURE ALL CLEARANCES (I.E. BACK, SIDE, TOP, VENT, MANTEL, FRONT, ETC.) ARE
WHEN USING PAINT OR LACQUER TO FINISH THE MANTEL, THE PAINT OR LACQUER MUST BE
Combustible materials may be installed fl ush with the front of the appliance but must not cover any of the black
face-areas of the appliance. Non-combustible material (brick, stone or ceramic tile) may protrude in these
areas.
Combustible mantel clearance can vary according to the
mantel depth. Use the graph to help evaluate the clear-
ance needed.
4.4

NAILING TAB INSTALLATION

A.
Attach the nailing tabs to the corner posts using the 2 sheet metal screws sup-
plied. Secure through the centre of the top and bottom slots in the nailing tab and
then through the existing holes in the corner posts. If there are no existing holes,
follow these instructions:
B.
To determine the fi nal location of the nailing tab you must fi rst determine the
thickness of your fi nishing material (i.e. drywall). This will determine the dimen-
sion from the front edge of the corner post to the nailing tab. Once the nailing tab
is in the desired location, drill through the centre hole of the nailing tab. Secure
with a sheet metal screw*.
* Additional set screws may be installed.
WARNING
!
CLEARLY MAINTAINED.
HEAT RESISTANT TO PREVENT DISCOLOURATION.
7
M
H
6
A
E
5
N
I
T
G
4
E
H
3
L
T
2
1
3
5
7
MANTEL WIDTH
7" MANTEL
6" MANTEL
7"
4" MANTEL
6"
2" MANTEL
4"
2"
TOP OF UNIT
73.1
COMBUSTIBLE
MATERIALS
STUD
NAILING TAB
55.1A
W415-0379 / E / 04.24.12
15