TEC MA-1350-1 Series Programming Manual page 49

Ma-1350-1 series electronic cash register
Hide thumbs Also See for MA-1350-1 Series:
Table of Contents

Advertisement

Address :
2
(Optional Functions 9)
Bit
No.
1
No. of PLUs Available
2
Cashier Identifying Function
3,4
5
Display of DPT Portion Selection 1
6
Display of DPT Portion Selection 2
7
Cashier Identifying Type Selection 1
8
Cashier Identifying Type Selection 2
Supplementary Description for Address 23:
Bit 1:
To select this bit to SET status, RAM of the capacity 128KB is necessary. This option must not
be programmed when the capacity of the RAM is 32KB.
Bit 2:
If SET status is selected, the register will operate without any cashier identifying operation. For
selecting the SET status, Be certain to take Daily and Periodical Cashier Reset Reports
beforehand to clear the cashier memory data. If those reports are not taken before changing the
bit to SET status, the cashier memory contents will not be guaranteed. The following will result
if SET status is selected.
Cashier Read/Reset report function cannot be used. An error will result on attempt to issue
any kind of cashier report.
An error will result when the [LOG/RECEIPT] key is depressed with a prior numeric entry
in sale entry mode.
Cashier No. (or name) print area on receipt, journal or validation slip will appear as blank
spaces.
Bits 5 & 6: If both RESET or both SET, Department/PLU Code is displayed on the DPT portion of
the display. If Bit 5 is selected to SET status, Cashier No. assigned to the cashier who
is in ON status will be always displayed. This selection is applied to all the cashier types.
Bit 7 & 8:
For details of each cashier type, refer to chapter 12 of the Operator's Guide in the Owner's
Manual.
Initial SET Bit Nos.
3
Content
-- vacant --
Even when Department/PLU item is entered, code assigned to each sales iem will not
be displayed, and Cashier No. will be kept displaying.
Even when the Food Stamp Feature is selected, Food Stamp Change will not be
displayed. If Bit 6 is selected to SET status, PLU Price Shift No. will be displayed.
Be certain to perform the Data Clear when the cashier type has been changed to another
to clear the sales data and perform the cashier OFF process.
Your Selection
- 47 -
MA-1350-1 SERIES
Selective Status
RESET
Max 1000PLU
Max 500PLU
Non-active
Active
Department/PLU
Cashier No.
Code or follow
Bit 6 status
Department/PLU
PLU Price
Code or follow
Bit 5 status
Barrel Lock, Push
Code Entry or
follow Bit 8 status
Code Entry or follow
[CLK] Key (SFKC)
Bit 7 status
EO3-11084
0
SET
Shift No.
LED Key

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ma-1350-1-s-usMa-1350-1f-s-us

Table of Contents