Service Manual TD70

Service menu TD70.2

S1
J1
Opening the service menu
Auto skåptorrt
Auto extratorrt
Tidsprogram
Check that the machine is switched off. Otherwise switch off the main power by pressing the
+
main power switch (S1).
Press and hold either of the buttons S2 and S3 while turning on the main power with the main
power switch (S1).
Press the button S2 3 times within 5 seconds. The service menu is now activated, as seen in
x 3
the display window. The service menu can be closed by turning off the power with the main
power switch (S1).
Press the Stop button (S9) to navigate the menu system step by step.
Turn the program selector (J1) to make selections from the menus.
T 7 5 3 C
B U T T E R F L Y
D R Y I N G
Confirm the selection and continue to the next menu by pressing the Stop button (S9).
Press the Start button (S10) to confirm the settings and exit the service menu.
T 7 5 3 C
B U T T E R F L Y
D R Y I N G
T 7 5 3 C
B U T T E R F L Y
D R Y I N G
Turn/
Display
Push
SP: xxxx
CM: xxxx
SV: xxxxxxxxx
NC: xxxxxxxxx
"Fault No. of cycles (1)"
T 7 5 3 C
B U T T E R F L Y
D R Y I N G
"Fault No. of cycles (2)"
"Fault No. of cycles (3)"
Test
T 7 5 3 C
B U T T E R F L Y
D R Y I N G
Test motor
Heater test 1
Heater test 2
Testing compressor
Testing steam heater
Testing steam pump
Testing switching valve
Testing Fan/Valve
Test drain
Test buzzer
T 7 5 3 C
B U T T E R F L Y
D R Y I N G
34
S2
S3
DISPLAY
Auto normaltorrt
Auto stryktorrt
Luftningsprogram
Comments/instructions
Date the software was programd (Year_Week)
Date of manufacture of the control unit (Year_Week)
Software version number
Number of cycles/programs run
Last three faults and number of cycles (when the fault occurred) shown.
A total reset deletes the fault indications from the system. If the same
fault recurs at different times, this is shown, but only once in the list.
No component tested
The motor runs at normal speed
The motor runs at normal speed. Heating element 1 is switched on and
off by the CU depending on the values registered by thermistors 1 and
2. Max. temp. 70°C. (Only if setting for heat pump is Heat Pump Off )
The motor runs at normal speed. Heating element 2 is switched on
and off by the CU depending on the values registered by thermistors 1
and 2. Max. temp. 70°C. (Only for condenser and vented machines and
where setting for steam is Steam Off )
Temperature sequence on (only machines with heat pump)
Steam heater on (only machines with steam function)
Steam pump on (only machines with steam function)
Switching valve on (only machines with heat pump)
Fan/Valve on (Fan only for machines with heat pump and Valve only for
HWC)
The condensed water pump starts (only condenser and heat pump
machines)
Buzzer on continuously
S4
S5
S6 S7
Panel key: S = Push button, J = Knob