  • Page 2 Content Page Tumble dryers TD70A TD73A TD76A TD77A 10-14...
  • Page 3 PROGRAM AND ELECTRICAL FEATURES TD 70 A General design TD 70 A have thermostat-controlled automatic programs to 47° C or 60° C and time programs up to 60 min. Alternative connections Alternative connections are single-phase, 230 V, 10 or 16 A with 1900 and 2850 W power respectively, 2-phase 400 V, 10 A, 2850 W (normal on delivery) 3-phase, 400 V, 10 A, 2850 W or 3-phase, 230 V, 16 A, 2850 W heating capacity.
  • Page 4 Thermostats There are four thermostats : The first is of 47°C and the second of 60°C, (for automatic programs) are fitted to the fan casing. The third of 115°C (resets automatically) operates at 115°C switching out one of the heaters if the temperature rises excessively. The fourth thermo- stat, also fitted to the heater casing, operates at 150°C and provides protec- tion against dangerous overheating.
  • Page 5 ELECTRICAL FEATURES TD 73A General design TD 73A is a vented dryer, which incorporate a microprocessor for process control, and pushbutton selection of programs. The pushbutton panel also carries LEDs and two-digit 7-segments displays which indicate selected time (for times programs), time-delayed starts etc.
  • Page 6 Overheating cutout The machine incorporates a manually-resettable overheating cutout, operating at a temperature of 150°C. Thermostat The thermostat has an automatic reset and the breaking temperature is of 115°C. It is used for indication of fluff in the filter or in the condenser. See fault signals F4.
  • Page 7 D2 D3 D4 S1.1 S1.2 S1.3 S1.4 S1.5 Program S1.1- Automatic programs S1.4 In this program the drying time is controlled by the microprocessor, depending on the moisture level measured by the moisture sensor and the dryness of the chosen program. The temperature is controlled by the thermistor to 60°C. By very small loads or empty machine, these programs will use a drying time of about 20 minutes.
  • Page 8 S5 Start/Stop Start a program by pressing the button and stop by pressing it for 3 seconds. S6 Time delayed start The start of a program can be delayed for 1-12 hours. Push the button so many times that you want the start to be delayed. By thirteenth press, the delay will be zero.
  • Page 9 Filter clogged The overheating cutout (150°C) will operate, and the machine stops.Must be reset manually. Moisture sensor not installed in the fan casing or fault in the control unit The machine stops after ca 20 min. Incoming suppIy fuses blown Fuse L1 blown: Machine will stop after ca.
  • Page 10 PROGRAM AND ELECTRICAL FEATURES TD 76 A General design TD 76 A has thermostat-controlled automatic programs to 47° C or 60° C and time programs up to 60 min. Alternative connections Alternative connections are single-phase, 230 V, 10 or 16 A with 1900 and 2850 W power respectively, 2-phase 400 V, 10 A, 2850 W (normal on delivery) 3-phase, 400 V, 10 A, 2850 W or 3-phase, 230 V, 16 A, 2850 W heating capacity.
  • Page 11 Signal lamp The signal lamp indicates that the main switch is ”on”. Driving motor The driving motor is a bi-polar unit with direct-coupling fan and gear facility for driving the drum. Capacitor The capacitor is 8 uF mounted on the component bridge. Heating element The heating element with 1900 + 950 W output is the spiral type.
  • Page 12 ELECTRICAL FEATURES TD 77A General design TD 77A is a condensing tumble dryer , which incorporate a microprocessor for process control, and pushbutton selection of programs. The pushbutton panel also carries LEDs and two-digit 7-segments displays which indicate selected time (for times programs), time-delayed starts etc.
  • Page 13 Overheating cutout The machine incorporates a manually-resettable overheating cutout, operating at a temperature of 150°C. Thermostat The thermostat has an automatic reset and the breaking temperature is of 115°C. It is used for indication of fluff in the filter or in the condenser. See fault signals F4.
  • Page 14 D2 D3 D4 S1.1 S1.2 S1.3 S1.4 S1.5 Program S1.1- Automatic programs S1.4 In this program the drying time is controlled by the microprocessor, depending on the moisture level measured by the moisture sensor and the dryness of the chosen program. The temperature is controlled by the thermistor to 75°C. By very small loads or empty machine, these programs will use a drying time of about 20 minutes.
  • Page 15 S5 Start/Stop Start a program by pressing the button and stop by pressing it for 3 seconds. S6 Time delayed start The start of a program can be delayed for 1-12 hours. Push the button so many times that you want the start to be delayed. By thirteenth press, the delay will be zero.
  • Page 16 Filter clogged The overheating cutout (150°C) will operate, and the machine stops.Must be reset manually. Moisture sensor not installed in the fan casing or fault in the control unit The machine stops after ca 20 min. Incoming suppIy fuses blown Fuse L1 blown: Machine will stop after ca.