Components And Function Description - Asko TD70 Service Manual

Tumble dryer
Hide thumbs Also See for TD70:
Table of Contents

Advertisement

Service Manual TD70
Component descriptions

Components and function description

Here we describe the function and
specification of the most important
components. Certain components are found
only in more highly specified machines or in
particular markets. See the Troubleshooting
chapter for fault and information codes.
CU (Control Unit)
The CU (Control Unit) functions as both a
control panel and a logic component. The
control panel is equipped with knobs/buttons
for selecting programs, Start/Stop buttons and
a display. It is an integrated part of the CU
and cannot be replaced separately. The logic
component manages functions needed for
drying programs and diagnosis. The CU has an
internal power supply for the logic component.
In the event of a fault, the CU can diagnose
a number of components and functions, and
a total of 4 fault codes can be displayed. To
facilitate troubleshooting there is a component
testing function in which the outputs are
activated according to a special sequence.
Power supply
Mains voltage, built-in internal voltage
converter for the logic component.
Light
Certain machines have an internal light
that is activated when the door is opened.
LED technology is used to improve energy
efficiency.
12
Thermistors
The thermistors are of the NTC type (Negative
Temperature Coefficient), which means their
resistance decreases as temperature increases.
Thermistor 1 is in the air duct on the front frame,
after the internal impeller. If there is an interruption
in the thermistor circuit or if it short circuits, the
drying program stops and the display shows
"Thermistor fault".
  Purpose: Measures the temperature of the air that
has passed the load and controls the drying process
and the heating element.
Thermistor 2 is on condenser dryers located after the
condenser and on heat pump dryers located on the
evaportator pipe by the comperssor. 
  Purpose: Measures the temperature of the
dehumidified air, the value of which is used as a
parameter in the drying process.
Resistance values for thermistors 1 and 2
Temperature
20°C
25°C
30°C
35°C
40°C
45°C
50°C
55°C
60°C
65°C
70°C
Tolerance: ±1%
Resistance
5989
4869
3946
3197
2598
2126
1758
1471
1240
1043
857