Service Menu And Settings; Service Menu Td70.1 - Asko TD70 Service Manual

Tumble dryer
Hide thumbs Also See for TD70:
Table of Contents

Advertisement

Service Manual TD70

Service menu TD70.1

L4
Auto Dry
Auto Extra Dry
S1
L3
L2
Paneltype A
Opening the service menu
Auto skåptorrt
Auto extratorrt
Tidsprogram
Check that the machine is switched off. Otherwise switch off the main power by pressing
+
the main power switch (S1). Press and hold the Start button (S10) while turning on the main
power with the main power switch (S1).
T 7 5 3 C
B U T T E R F L Y
D R Y I N G
Press the Start button (S10) 5 times within 5 seconds. The service menu is now activated,
which is indicated by L2 flashing. The service menu can be closed by turning off the power with
x 5
the main power switch (S1).
T 7 5 3 C
B U T T E R F L Y
D R Y I N G
Press the button S7 to navigate the menu system step by step.
Turn the program selector (J1) to make selections from the menus.
T 7 5 3 C
B U T T E R F L Y
Confirm the selection and continue to the next menu by pressing the button S7.
Press the Start button (S10) to confirm the settings and exit the service menu.
T 7 5 3 C
T 7 5 3 C
B U T T E R F L Y
D R Y I N G
Turn/
Indication
Push
L2 flashes
L2 and L4 flash
L2 and L7 flash
L2, L7 and L9 flash
L2 and L9 flash
T 7 5 3 C
B U T T E R F L Y
L33 flashes
L34 flashes
L35 flashes
L36 flashes
L37 flashes
Press the button S7 to return to the beginning of the service menu
T 7 5 3 C
B U T T E R F L Y
Press the Start button (S10) to confirm the settings and exit the service menu.
T 7 5 3 C
B U T T E R F L Y
D R Y I N G
32
L7
Auto Normal Dry
Auto Iron Dry
J1
L9
L8
Auto normaltorrt
Auto stryktorrt
Luftningsprogram
D R Y I N G
B U T T E R F L Y
D R Y I N G
Comments/instructions
No component tested
The motor runs at normal speed
The motor runs at normal speed. Heating element 1 is switched on
and off by the CU depending on the values registered by thermistors 1
and 2. Max. temp. 70°C.
The motor runs at normal speed. Heating element 2 is switched on
and off by the CU depending on the values registered by thermistors 1
and 2. Max. temp. 70°C.
The condensed water pump starts (condenser machines only)
D R Y I N G
Drying time extended by 0, default setting
Drying time extended by 5 min
Drying time extended by 10 min
Drying time extended by 15 min
Drying time extended by 20 min
D R Y I N G
S4
S7
L33
L32
L24
L29
Panel key: S = Push button, J = Knob, L = LED
S11
L34
L35
T 7 4 3 C
B U T T E R F L Y
D R Y I N G
L37
S10
L36
T 7 5 3 C
B U T T E R F L Y
D R Y I N G

Advertisement

Table of Contents
loading

Table of Contents