4) Remove the three screws, and disconnect
the connector; then, detach the DC PCB
[4] and the support plate [5].
[5]
[4]
Figure 10-519
5) Remove the ten screws, and detach the
key switch PCB [6].
Figure 10-520
COPYRIGHT © 1999 CANON INC. CANON imageRUNNER 400/330 REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 10 EXTERNALS/AUXILIARY MECHANISMS
[6]
D. DC Controller PCB
1) Disconnect the power plug.
2) Remove the four screws, and detach the
rear cover.
3) Remove the three screws, and detach the
flywheel.
4) Remove the screw [2], and disconnect the
connector [3]; then, detach the cleaner
cooling fan [1] together with its stay.
Figure 10-521
5) Remove the eight screws [4], and
disconnect all connectors; then, detach the

DC controller PCB [5].

[5]
[4]
[4]
Figure 10-522
[1]
[2]
[3]
[4]
[4]
10-23