AIR CLEANER
If the air cleaner element has become
clogged with dust, intake resistance will
increase with a resultant decrease in power
output and an increase in fuel consumption.
If riding under severe conditions must be
cleaned or replaced more frequently than
maintenance schedule. Check and clean
the air cleaner element periodically
according to the following procedure.
CAUTION
If the air cleaner element is polluted, it
will occur to starting go out, output
insuffiency, combustion effciency
decline, and sooty smoke(black smoke).
This appearence occures at first to clean
the air cleaner element and confirm.
1. Remove the seat and right side cover.
2. Remove the six screws ①
the air cleaner case cover.
3. Take off the air cleaner element ② .
and remove
46
4. Fill a washing pan of a proper size with
nonflammable cleaning solvent �
lmmerse the element in the cleaning
solvent and wash it clean.
5. Squeeze the cleaning solvent out of the
washed element by pressing it between
the palms of both hands : do not twist or
wring the element or it will develop tears.
6. Immerse the element in HYOSUNG
genuine oil � and squeeze the oil out of
the element leaving it slightly wet with oil.
7. Clean any dirt or debris from inside the air
cleaner case.
Be sure no dirt enters the carburetor.
8. Reinstall the cleaned element in reverse
order of removal.
Be sure that the element is securely in
position and is properly sealed.
. .