Table 2-7 Zone Transceiver Ii Range; Cabling Precautions; Environmental Conditions; Power Requirements - NEC Electra Elite 192 Hardware Manual

Table of Contents

Advertisement

Issue 6
2 - 8

Table 2-7 Zone Transceiver II Range

Connected Equipment
ZT II-U Unit without ACA-U Unit
ZT II-U Unit with ACA-U Unit
4.2

Cabling Precautions

4.2.1
Cable Placement
When selecting cables and Main Distribution Frame
(MDF), future expansion or assignment changes should
be considered. Avoid running cables in the following
places:
¥
¥
¥
4.2.2

Environmental Conditions

Temperature
¥
¥
Humidity
¥
4.3

Power Requirements

4.3.1

Power Supply Inputs

AC input requirements for the system are listed below.
AC Input (P64-U10 PSU)
¥
¥
¥
¥
¥
A place exposed to wind or rain.
A place near heat radiating equipment or where the
quality of station cable covering could be affected
by gases and chemicals.
An unstable place subject to vibration.
Operating:
+32°F ~ +104°F (0°C ~ 40°C)
Long Term:
+50°F ~ +90°F (10°C ~ 32.2°C)
Operating:
10% ~ 90% noncondensing
117 Vac ± 10%
60 Hz ± 10%
Single Phase
7.5A circuit
A dedicated outlet, separately fused and grounded
Electra Elite
Range
3,000 feet
16,404 feet
System Specifications