Checking and acknowledging faults
Fault code
Const.
in the dis-
play
F2
X
F3
X
F4
X
Weat-
System
h.
character-
comp.
istics
X
Burner in
fault state
X
Burner in
fault state
X
Burner in
fault state
Troubleshooting
(cont.)
Cause
Remedy
Temperature limiter
Check the
has responded
heating sys-
tem water
level. Check
the circula-
tion pump.
Vent the heat-
ing system.
Check the
temperature
limiter and
leads.
Press E.
The flame signal is
Check the
already present at
ionisation
burner start
electrode and
leads.
Press E.
No flame signal is
Check the
present
ionisation
electrode and
leads, mea-
sure the ioni-
sation cur-
rent, check
the gas pres-
sure, check
the gas com-
bination
valve, igni-
tion, ignition
module, igni-
tion electro-
des and the
condensate
drain.
Press E.
81