Viessmann VITODENS 333 Service Instructions Manual page 60

Compact gas fired condensing boiler natural gas and lpg version
Hide thumbs Also See for VITODENS 333:
Table of Contents

Advertisement

Coding
Code 2
(cont.)
Coding in
Function mode
the as
delivered
condition
Address:
value
F2:8
*
3
Time limit for party
operation 8 hours or
external operating
mode changeover via
push button
F5:12
*
5
*
5
Run-on time of the
internal circulation
pump in heating mode
*3
Only for weather-compensated control unit.
In heating program "rw", the party mode ends automatically when changing over to
*4
operation with standard room temperature.
*5
Only for constant temperature control units.
60
Coding
change
Address:
value
F1:6
to
F1:15
F2:0
F2:1
to
F2:12
*
4
F5:0
F5:1
to
F5:20
Possible change
must contain the follow-
ing heat-up details:
&
Heat-up data with
respective flow tem-
peratures
&
Max. flow temperature
achieved
&
Operating condition
and outside tempera-
ture during handover
The function continues
after power failure or
after the control unit has
been switched OFF. The
heating program "rw"
will be started, after the
screed-drying function
has been completed or if
the address is manually
set to 0.
Constant flow tempera-
ture 20 °C
No time limit for party
mode
Time limit adjustable from
*
4
*
4
1 to 12 hours
No run-on time of the
internal circulation pump
Run-on time of the inter-
nal circulation pump
adjustable from 1 to