Coding
Code 2
(cont.)
Coding in
Function mode
the as
delivered
condition
Address:
value
59:0
DHW cylinder loading:
Starting point -2.5 K
Stopping point +2.5 K
60:10
During DHW loading,
the boiler water tem-
perature is a maximum
of 20 K higher than the
set DHW temperature
62:2
Circulation pump with 2
minutes run-on time
63:0
*
1
Without auxiliary func-
tion for DHW loading
65:...
Information regarding
the type of diverter
valve (not adjustable)
6C:100
Set speed internal DHW
loading pump 100 %
6F:100
Max. output during
DHW loading 100 %,
defaulted by the boiler
coding card
*1
Only for constant temperature control units.
48
Coding
Possible change
change
Address:
value
59:1
Starting point adjustable
to
from 1 to 10 K below the
59:10
set value
60:5
The difference between
to
the boiler water tempera-
60:25
ture and the set DHW
temperature is adjustable
from 10 to 50 K
62:0
Circulation pump without
run-on
62:1
Run-on time adjustable
to
from 1 to 15 minutes
62:15
63:1
Additional function: 1 x
daily
63:2
Every 2 to every 14 days
to
63:14
63:15
2 x daily
65:0
Without diverter valve
65:1
Diverter valve by Viess-
mann
65:2
Diverter valve by Wilo
65:3
Diverter valve by Grund-
fos
6C:0
Set speed adjustable
to
from 0 to 100 %
6C:100
6F:0
Max. output during DHW
to
loading adjustable from 0
6F:100
to 100 %