Resolute Acclaim Clearance Chart - Vermont Castings Resolute Acclaim 2490 Homeowner's Installation And Operating Manual

Woodburning stove
Table of Contents

Advertisement

Resolute
®
Acclaim Woodburning Stove
Stove clearance
No heat shields
Top exit, rear heat
shield only
1
Rear exit, rear heat
shield only
Top exit, rear h.s.,
single-wall connector,
connector shields
1,2
Top exit, rear h.s.,
double-wall connec-
tor
1,3
chimney connector
clearance
No Heat Shields
Chimney connector
heat shields
2
Double-wall connector
3
Front clearance
to combustibles**
* Clearances with double-wall connectors and protected surfaces have not been tested for the Resolute Ac-
claim.
** A distance of 48" must be maintained between the stove and moveable combustible items such as drying
clothes, furniture, firewood, etc.
When a rear heat shield is installed on a top exit stove, the shield insert must be attached to the shield so the
1
area behind the flue collar on the stove is protected.
Chimney connector heat shields must extend exactly 28" (710 mm) above the flue collar of the stove. No
2
shielding can be used on the connector above 28" (710 mm). The unshielded chimney connector above the
28" (710 mm) point will be 14" (360mm) from an unprotected wall or 8" (203 mm) from a protected wall.
In top exit installations, this clearance requires the use of the rear stove heat shield with the shield insert
3
installed.
12

Resolute Acclaim clearance chart

Unprotected Surface
parallel installation
Side
Rear
(A) 15"
(B) 24"
(380 mm)
(610 mm)
(G) 15"
(H) 24"
(380 mm)
(610 mm)
(M) 15"
(N) 10"
(38 mm)
(254 mm)
(Q) 15"
(R) 15"
(380 mm)
(380 mm)
(Q) 15"
(R) 17"
(380 mm)
(432 mm)
23" (580 mm)
14" (360 mm)
16" (410 mm)
corner
installation
Corner
(C) 15"
(D) 8"
(380 mm)
(203 mm)
(I) 15"
(J) 8"
(380 mm)
(203 mm)
N/A
(O) 8"
(203 mm)
(S) 15"
(T) 8"
380 mm)
(203 mm)
(S) 15"
(380 mm)
All Installations
48" (1220 mm)
protected Surface
parallel installation
Side
Rear
(E) 13"
(330 mm)
(K) 13"
(330 mm)
(P) 7"
(180 mm)
(U) 9"
(23 mm)
*
12" (305 mm)
8" (203 mm)
*
corner
installation
Corner
(F) 8"
(203 mm)
(L) 8"
(203 mm)
N/A
(V) 8"
(203 mm)
2000893

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents