Defiant Clearance Chart - Vermont Castings Defiant 1945 Homeowner's Installation And Operating Manual

Vermont castings woodburning stove home owner's installation and operating manual 1945
Hide thumbs Also See for Defiant 1945:
Table of Contents

Advertisement

for use with either a 6" or 8" chimney connection
No stove
heat shields
Stove, top exit with rear
heat shield, no connector
heat shields
Stove, top exit with rear
heat shield, and heat
shields on connector
Stove, top exit with rear
heat shield, and double-
wall chimney connector*
Stove, rear exit with rear
heat shield only
Single-wall connector
Single-wall connector;
rear heat shield on
stove only
Single-wall connector
with shields, and rear heat
shield on stove
Double-wall chimney con-
nector
Single-wall connector
* Using a listed double wall oval to round connector.
30001693
Defiant Clearance Chart
Unprotected Surfaces
Stove Installed
Parallel to Wall
Side
Rear
(A) 24"
(B) 33"
(610 mm)
(840 mm)
(G) 24"
(H) 21"
(610 mm)
(533 mm)
(M) 24"
(N) 17"
(610 mm)
(430 mm)
(S) 24"
(T) 17"
(610 mm)
(430 mm)
(Y) 27"
(Z) 24"
(686 mm)
(610 mm)
Chimney Connector Clearance
Unprotected Vertical Surfaces
30" (760 mm)
18" (460 mm)
14" (355 mm)
14" (355 mm)
Unprotected or Protected Ceiling Surfaces
Clearance to Combustibles in Front of Stove
All Installations
Stove Clearance
Protected Surfaces
Stove
Stove Installed
in
Parallel to Wall
Corner
Corners
Side
(C) 23"
(D) 14"
(585 mm)
(355 mm)
(I) 17"
(J) 14"
(430 mm)
(355 mm)
(O) 17"
(P) 14"
(430 mm)
(355 mm)
(U) 17"
(V) 14"
(430 mm)
(355 mm)
N/A
(AA) 17"
(430 mm)
Protected Vertical Surfaces
24" (610 mm)
48" (1220 mm)
Defiant Woodburning Stove
Stove
in
Corner
Rear
Corners
(E) 28"
(F) 18"
(710 mm)
(460 mm)
(K) 17"
(L) 12"
(430 mm)
(305 mm)
(Q) 17"
(R) 12"
(430 mm)
(305 mm)
(W) 15"
(X) 12"
(380 mm)
(305 mm)
(BB) 20"
N/A
(508 mm)
25" (635 mm)
14" (355 mm)
14" (355 mm)
12" (305 mm)
13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents