Sony SRX-R320 Installation Manual page 98

Digital cinema projector
Hide thumbs Also See for SRX-R320:
Table of Contents

Advertisement

Message No.
Error message
WARN_26
DOUSER ERROR
WARN_27
BALLAST ERROR
WARN_28
BALLAST ERROR
WARN_29
EXHAUST ERROR
WARN_30
COVER DETACHED
WARN_31
FAN ERROR
WARN_32
FAN ERROR
WARN_33
FAN ERROR
*1: Warning is displayed when the air volume at the outlet of the 8-inch duct is under 250 ft
The exhaust air volume required is 450 to 550 ft
FAILURE (Degree of risk: low)
Message No.
Error message
FAIL_02
TEMPERATURE ERROR
FAIL_04
TEMPERATURE ERROR
FAIL_06
TEMPERATURE ERROR
FAIL_10
TEMPERATURE ERROR
FAIL_11
TEMPERATURE ERROR
FAIL_12
TEMPERATURE ERROR
FAIL_15
TEMPERATURE ERROR
FAIL_16
LENS ERROR
FAIL_17
LENS ERROR
FAIL_18
LENS ERROR
3-4
Trouble
DOUSER operation is failed.
A power unit for lamp communication
failed.
Lamp serial number setting is wrong.
The air volume of the 8-inch duct is
abnormal.
The fi lter cover is detached.
PS converter fan 2 in abnormal.
PS converter fan 1 in abnormal.
PBS fan in abnormal.
/min (12.7 to 15.6 m
/min).
3
3
Trouble
Warning for temperature abnormality of
the 8-inch duct.
Intake temperature is abnormal.
The optical unit block temperature is
abnormal.
Warning for temperature abnormality of
the R panel.
Warning for temperature abnormality of
the G panel.
Warning for temperature abnormality of
the B panel.
Warning for temperature abnormality of
the power unit for lamp.
Zoom does not reach the registered
position.
Focus does not reach the registered
position.
Zoom operation is failed.
Remedy
Check the connector of a shift block.
Check the shift block. Replace the shift
block if it is damaged.
Check the cable between the power unit
for lamp and lamp house. Check the
power unit for lamp. Replace the power
unit for lamp if it is damaged.
Check the range setting of power unit for
lamp and the serial information of a lamp.
Check the air volume at the outlet of the
8-inch duct.*1
Check that the fi lter cover (door) is not
opened.
Check the PS converter fan 2. Replace
the PS converter fan 2 if it is damaged.
Check the PS converter fan 1. Replace
the PS converter fan 1 if it is damaged.
Check the PBS fan. Replace the PBS fan
if it is damaged.
/min (7 m
/min).
3
3
Remedy
Check the outside air temperature, the
suction amount of a 8-inch duct, and the
lamp cooling fans.
Check the outside air temperature.
Check the outside air temperature, and air
supply and exhaust.
Check the outside air temperature, and air
supply and exhaust. Check the Peltier R.
Replace the Peltier R if it is damaged.
Check the outside air temperature, and air
supply and exhaust. Check the Peltier G.
Replace the Peltier G if it is damaged.
Check the outside air temperature, and air
supply and exhaust. Check the Peltier B.
Replace the Peltier B if it is damaged.
Check the outside air temperature. Check
the power unit for lamp. Replace the
power unit for lamp if it is damaged.
Check the function operation, lens, and
lens cable. Check the SY board. Replace
the SY board if it is damaged.
Check the function operation, lens, and
lens cable. Check the SY board. Replace
the SY board if it is damaged.
Check the lens and lens cable. Check the
SY board. Replace the SY board if it is
damaged.
(Continued)