Carrier 50TFQ004 Product Data page 18

Single-package standard efficiency rooftop heat pump units 3 to 10 nominal tons
Table of Contents

Advertisement

Performance data (cont)
50TFQ008 (7
1
/
TONS)
2
Temp (F)
Outdoor
Entering Air
(Edb)
72
TC
109.8
75
SHC
44.2
kW
6.66
TC
105.2
85
42.8
SHC
kW
7.20
TC
100.6
95
SHC
41.6
kW
7.78
TC
94.8
105
SHC
40.0
kW
8.26
TC
88.8
115
SHC
38.4
8.76
kW
TC
82.6
125
SHC
36.8
kW
9.20
1
50TFQ009 (8
/
TONS)
2
Temp (F)
Outdoor
Entering Air
(Edb)
72
TC
111.4
75
SHC
51.8
kW
8.64
TC
108.8
85
SHC
50.9
kW
9.27
TC
104.5
95
SHC
49.3
kW
9.90
98.8
TC
105
SHC
47.1
kW
10.37
TC
93.8
115
SHC
45.3
10.99
kW
TC
88.4
125
SHC
43.4
kW
11.52
LEGEND
— Bypass Factor
BF
Edb — Entering Dry-Bulb
Ewb — Entering Wet-Bulb
kW — Compressor Motor Power Input
Ldb — Leaving Dry-Bulb
Lwb — Leaving Wet-Bulb
SHC — Sensible Heat Capacity (1000 Btuh) Gross
TC
— Total Capacity (1000 Btuh) Gross
18
COOLING CAPACITIES (cont)
2250/0.04
3000/0.06
67
62
72
101.4
92.2
116.2
57.4
69.4
49.6
6.44
6.18
6.86
96.4
87.0
111.4
55.6
67.6
48.4
6.94
6.64
7.42
91.0
82.0
105.6
54.0
65.8
47.0
7.42
7.08
7.96
85.4
76.8
99.8
52.2
63.8
45.6
7.88
7.50
8.48
79.9
71.4
93.4
50.4
61.6
44.2
8.32
7.90
8.98
73.8
65.8
86.6
48.6
59.2
42.2
8.74
8.30
9.44
2400/0.06
3200/0.09
67
62
72
102.3
91.0
115.7
64.3
75.3
54.9
8.48
8.23
9.32
97.4
86.1
113.7
62.3
73.2
54.7
9.09
8.76
9.98
92.7
81.2
110.4
60.2
70.9
53.7
9.56
9.22
10.64
87.8
75.9
105.5
58.3
68.1
52.2
10.08
9.70
11.26
82.4
71.1
98.7
56.0
65.9
49.5
10.56
10.13
11.72
77.2
66.7
93.1
54.1
63.1
47.7
11.03
10.56
12.33
Indoor Entering Air — Cfm/BF
3200/0.08
Indoor Entering Air — Ewb (F)
67
62
72
107.0
98.0
117.6
108.8
66.0
82.0
51.8
6.60
6.36
6.92
102.2
92.6
113.0
104.0
65.0
80.0
50.8
7.14
6.82
7.48
96.2
87.4
107.2
63.2
77.8
49.4
7.62
7.30
8.00
90.2
82.2
101.4
61.6
74.6
48.2
8.10
7.76
8.56
84.0
77.6
94.8
59.8
70.6
46.6
8.54
8.22
9.04
77.4
74.4
88.0
57.8
66.2
45.2
8.96
8.68
9.52
Indoor Entering Air — Cfm/BF
3600/0.11
Indoor Entering Air — Ewb (F)
67
62
72
108.2
97.6
117.0
110.1
71.9
87.6
55.8
9.18
8.95
9.73
104.2
92.9
115.2
106.6
70.9
85.1
55.7
9.79
9.40
10.40
10.24
98.8
87.7
112.0
101.3
68.7
82.4
55.1
10.39
9.88
11.07
10.86
93.4
83.0
107.4
66.5
79.0
53.7
10.90
10.33
11.71
11.34
87.9
78.6
100.8
64.5
75.5
51.3
11.39
10.79
12.16
11.86
82.2
74.5
94.9
62.3
71.4
49.2
11.87
11.30
12.78
12.33
NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:
sensible capacity (Btuh)
t
= t
ldb
edb
t
= Wet-bulb temperature corresponding to enthalpy of air leav-
lwb
ing indoor coil (h
h
= h
lwb
ewb
Where: h
= Enthalpy of air entering evaporator coil
ewb
3. The SHC is based on 80 F edb temperature of air entering indoor
coil.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
3750/0.11
67
62
72
100.2
118.8
69.8
87.0
54.0
6.66
6.42
6.94
95.0
114.6
69.0
84.4
53.4
7.20
6.90
7.54
98.0
89.8
108.6
67.4
81.4
52.0
7.70
7.40
8.06
91.6
85.0
103.2
65.8
77.6
51.2
8.18
7.88
8.64
85.4
80.0
96.0
64.0
73.2
49.4
8.62
8.36
9.10
78.8
75.0
89.2
62.0
68.6
48.2
9.02
8.82
9.60
4000/0.14
67
62
72
100.4
118.1
74.9
92.5
56.7
9.61
9.30
10.19
94.8
116.6
74.3
89.3
56.7
9.83
10.88
90.8
113.2
72.6
86.3
56.2
10.25
11.55
95.4
86.5
108.9
69.9
82.2
55.1
10.73
12.20
89.8
82.1
102.9
68.0
77.9
53.0
11.24
12.76
83.9
77.9
96.2
65.8
73.7
50.4
11.75
13.29
1.10 x cfm
)
lwb
total capacity (Btuh)
4.5 x cfm
67
62
110.4
102.4
74.0
92.0
6.70
6.48
105.8
97.6
73.8
88.8
7.28
7.00
99.6
92.8
72.2
84.6
7.76
7.50
93.2
88.0
70.4
80.4
8.24
8.02
86.6
83.0
68.6
75.8
8.70
8.50
80.0
77.6
66.6
71.0
9.12
8.98
67
62
111.6
102.5
77.1
96.4
10.12
9.72
108.3
98.0
77.2
92.2
10.74
10.20
103.1
93.8
75.7
88.2
11.36
10.67
97.1
89.5
72.9
83.9
11.82
11.24
91.3
85.3
71.0
79.6
12.38
11.76
85.3
80.8
68.8
75.2
12.81
12.27

Hide quick links: