Detailed Status - Comtech EF Data SLM-5650A Installation And Operation Manual

Satellite modem
Hide thumbs Also See for SLM-5650A:
Table of Contents

Advertisement

SLM-5650A Satellite Modem
Front Panel Operation
Demod: ----
Intf: +--------
Monitor: Alarms
Unit: ----------------
Press [ENT] to access the available read-only SLM-5650A Unit alarm screens. Then, use the
 arrow keys to navigate through the displayed character positions (Unit#1 through #23). The
status message to the right changes based on the current cursor position, as per the following
table:
Unit Alarm Position
Top row
Bottom row
The example that follows depicts the alarm status screen displayed if the Unit 1
position is selected:
Unit: +---------------
Unit
-------
Description
Unit #1
+ 5 volt power supply is out of range.
Unit #2
+ 3.3 volt power supply is out of range.
Unit #3
+ 2.5 volt power supply is out of range.
Unit #4
+ 1.5 volt power supply is out of range.
Unit #5
+ 12 volt power supply is out of range.
Unit #6
- 12 volt power supply is out of range.
Unit #7
+ 18 volt power supply is out of range.
Unit #8
Cooling fan fault.
Unit #9
External reference activity status.
Unit #10
192 MHz clock Phase Lock Loop status.
Unit #11
10 MHz reference Phase Lock Loop status.
Unit #12
M&C FPGA configuration fault.
Unit #13
Modulator FPGA configuration fault.
Unit #14
Demodulator FPGA configuration fault.
Unit #15
Decoder FPGA configuration fault.
Unit #16
Transmit interface FPGA configuration fault.
Unit #17
Receive interface FPGA configuration fault.
Unit #18
FEC #1 FPGA configuration fault.
Unit #19
FEC #2 FPGA configuration fault.
Unit #20
Optional data interface card (module) FPGA configuration fault.
Unit #21
FPGA DCM Phase Lock Loop fault.
Unit #22
Network Processor mailbox communications error.
Unit #23
TRANSEC mailbox communications error.
-----
Demux not
locked
Press <ENT> for

detailed status

+5.0V Power is
out of range.
5–36
Revision 8
MN-SLM5650A
st
character

Advertisement