lightning discharge ground is only used by the lightning protection system and is irrelevant for the rest of the
switch system.
Figure 2-3 Diagram showing the schematic for the grounding points at the back of the DGS-6604
The power cables that the Switch uses must ensure normal operation. Before connecting any cables to the
Switch, carefully read the precautions in the next few pages.

EMI Considerations

The system can be affected by various sources of interference. Interference can affect the system in several
conductive ways, including capacitive coupling, inductive coupling, and electromagnetic radiation.
The two types of electromagnetic interference are conductive interference and radiated interference. The type of
electromagnetic interference will vary depending on the type of propagation path.
Radiated interference refers to the energy, usually RF energy, that arrives at a sensitive component through the
air. The source of the interference can either be from the system that is affected by interference or from a
different unit. The electromagnetic wire or signal cable connections between the source and sensitive
components can cause conducted interference results. A cable that is affected by interference can conduct
interference to other units in the network. The power supply unit of equipment is most often affected by
conductive interference. A filter can be used to control interference problems. However, signal paths in the
equipment may be affected by radiated interference, making it difficult to shield against.
1. In order to prevent interference from the power grid, effective measures should be taken against conductive
interference within units the power system.
2. The grounding device of the power equipment or the anti-lightning grounding device should ideally be
located as far away as possible from the working ground of the router.
3. Ensure that high-frequency large-current devices, high-power radio transmitters, and radar transmitting
stations are kept away from the Switch.