X6^
= Event status field:
event_type
event_state
event_paused
error_status
RcvBuff_startptr
RcvBuff_endptr
UsrBuff_startptr
UsrBuff_endptr
X6&
= ASCII digits representing the numeric value of the data element read from the event
buffer. (Leading zeros are suppressed.)
X6*
= Parameter to set either the Length of the message to receive or a Delimiter value
L = byte count (min = 0, max = 32767, and default = 0L [0 byte count])
D = decimal value for the ASCII character (min = 0, max = 00255, and
default = 00000L)
This value is placed before the parameter; for example, 3 byte length = 3L, and the
ASCII 0A delimiter is 10D. The response contains leading zeros.
This parameter is case sensitive; you must use uppercase D and L.
NOTE:
X6(
= Priority status for receiving timeouts.
0 = use Send data string command parameters
1 = use Configure receive timeout command parameters
Default = 0.
X7)
= Verbose mode and tagged response status. In verbose mode, system responses
to entries made via other connections are displayed. Tagged responses include the
command entered as well as the response of the unit to it.
0 = neither verbose mode nor tagged responses enabled (default for IP connection)
1 = verbose mode enabled; no tagged responses (default for serial connection)
2 = tagged responses enabled; verbose mode not enabled
3 = both verbose mode and tagged responses enabled
HDXP Plus Series Switchers • Remote Configuration and Control