3. Specifications
Input system
Number of input points
Isolation system
Rated input voltage
Rated input current
Operating voltage range
Max. number of
simultaneous input points
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
ON to OFF
time *1
OFF to ON
Dynamic scan cycle
Output system
Number of output points
Isolation system
Rated load voltage
Max. load current*4
Operating load voltage
range
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
ON to OFF
Response
time*1
OFF to ON
Surge suppressor
Input Specifications
Dynamic scan
8/64 points
Photocoupler isolation
12VDC
Approx. 4mA
10.2 to 26.4VDC (ripple percentage within 5%)
100% simultaneous ON (at 26.4VDC)
8VDC or more/2mA or more
4VDC or less/1mA or less
Approx. 2.4KΩ
Approx. 0.4ms or less (24VDC)
Approx. 0.4ms or less (24VDC)
13.3ms
Output Specifications
Direct
16 points
Photocoupler isolation
12/24DVC
0.1A/1 point
10.2 to 26.4VDC (ripple percentage within 5%)
0.4A
0.1mA or less
2.5VDC (0.1A)
2ms or less
2ms or less (resistive load)
Clamp diode
2
24DVC
Approx. 9mA