ried out:
• domestic hot water heat exchanger;
• condensing heat exchanger;
• burner;
• exhaust fume duct and flue;
• pressurisation of the expansion tank;
• filling up of the central heating circuit;
• bleeding of air from the central heating
system;
• general check of the appliance's opera-
tion.
3.5

External cleaning

Before carrying out any clean-
ing, disconnect the appliance
from the electrical mains, using
the fused spur isolation switch
fitted adjacent to the appliance.
To clean the external panels, use a cloth
soaked in soapy water. Do not use solvents,
abrasive powders or sponges.
Do not carry out cleaning of the appliance
and/or its parts with readily flammable sub-
stances (for example petrol, alcohols, naph-
tha, etc.).
3.6

Operational faults

If the boiler does not function and a code
that alternates between the letter Er and the
writing RESET (see "LCD general features"
to page 9) appear on the LCD display, it in-
dicates that the safety lock-out has stopped
the boiler. The display background flashes
(Fig. 3.3).
USEFUL ADVICE
Fig. 3.3
For the first lighting up and following main-
tenance procedures for the gas supply, it
may be necessary to repeat the resetting
operation several times so as to remove the
air present in the pipe work.
Safety lock-out may occur even in case of a
blockage of the condensate drainage (e.g.
plugged drain pipe). It is advisable to check
the condensate drainage pipe and traps for
cleanness.
Press the reset key on the boiler control
panel 14 (Fig. 3.1) to reset its functioning.
Other operational faults signalled on the
LCD display
If the LCD display displays a code that al-
ternates between the letter Er and the
symbol, the boiler has an anomaly that can-
not be reset.
The display background flashes (Fig. 3.4).
RESET
RESET
In this case and in case of per-
sistent lock-out call a compe-
tent and responsible Service
Engineer.