7.12 Setting the pump post-circula-
tion
The pump, in heating function, is set for a
post-circulation of about one minute at the
end of each heat request.
This time can be changed by a minimum of
zero to a maximum of four minutes by act-
ing on programming both from the panel
controls and the remote control.
• Enter in "programming mode" by pressing
keys 14 - 15 - 16 (Fig. 7.24) for 10 seconds
COMMISSIONING
to display the K REG
at the same time until the letters Pr that al-
ternate with code 01 are displayed on the
LCD display, indicating that "parameter
01" (Fig. 7.25) has been activated.
12
13
Fig. 7.24
Fig. 7.25
• Scroll the various parameters using keys
15 or 16 until the letters Pr that alternate
with code 11 are displayed on the LCD
display, indicating that "parameter 11"
(Fig. 7.26) has been activated.
16
15
14