Min Max Recording Specifications - Fluke 88 V User Manual

Automotive multimeter
Hide thumbs Also See for 88 V:
Table of Contents

Advertisement

Model 88 V
Users Manual
Nominal Response
100 ms to 80 %
(dc functions)
120 ms to 80 %
(ac functions)
250 µs (peak)
1
1.
For repetitive peaks: 1 ms for single events.
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176
74
Table 20. Min Max Recording Specifications
Specified accuracy ± 12 counts for changes > 200 ms in duration
Specified accuracy ± 40 counts for changes > 350 ms and inputs > 25 % of range
Specified accuracy ± 100 counts for changes > 250 µs in duration
(add ± 100 counts for readings over 6000 counts)