Detailed Specifications; Ac Voltage Function Specifications - Fluke 88 V User Manual

Automotive multimeter
Hide thumbs Also See for 88 V:
Table of Contents

Advertisement

Weight:.......................................................................... 12.5 oz (355 g)
Weight with Holster and Flex-Stand:......................... 22.0 oz (624 g)
Safety: ........................................................................... Complies with ANSI/ISA S82.01-2004, CSA 22.2 No. 1010.1:2004 to

Detailed Specifications

For all detailed specifications:
Accuracy is given as ± ([% of reading] + [number of least significant digits]) at 18° C to 28° C, with relative humidity up to
90 %, for a period of one year after calibration. AC conversions are ac coupled and are average responding, rms indicating.
Function
Range
K
600.0 mV
1
6.000 V
60.00 V
600.0 V
1000 V
1.
Below a reading of 200 counts, add 10 counts.
2.
Frequency range: 1 kHz to 2.5 kHz.
1000 V Overvoltage Category III, IEC 664 to 600 V Overvoltage
Category IV. UL listed to UL61010-1. Licensed by TÜV to EN61010-1.
Table 12. AC Voltage Function Specifications
Resolution
50 Hz - 60 Hz
± (0.5 % + 4)
0.1 mV
± (0.5 % + 2)
0.001 V
± (0.5 % + 2)
0.01 V
± (0.5 % + 2)
0.1 V
± (0.5 % + 2)
1 V
Automotive Multimeter
Accuracy
30 Hz - 1 kHz
± (1.0 % + 4)
± (1.0 % + 4)
± (1.0 % + 4)
± (1.0 % + 4)
± (1.0 % + 4)
Specifications
1 kHz - 5 kHz
± (2.0 % + 4)
± (2.0 % + 4)
± (2.0 % + 4)
± (2.0 % + 4)
2
unspecified
667

Hide quick links: