Test pressures

To check and set the burner pressures
1. Refer to the data plate located inside the appliance on the front left hand side for the
correct gas pressure settings.
2. Using a screw driver loosen the captive Appliance Test Point Pressure Screw (ATPP) and fit
the manometer.
3. Remove the dust cap from the regulator adjusting nut and screw.
Gas control valve
Low pressure
adjusting screw
Gas outlet
Appliance test point
pressure
Rinnai New Zealand Limited
High pressure
adjusting nut
Gas control power connection
22
Gas
inlet
Inlet test
point
Cap