Stick On Label; Pressure Testing - Rangemaster Classic 90 Dual Fuel User's Manual & Installation Instructions

Dual fuel
Hide thumbs Also See for Classic 90 Dual Fuel:
Table of Contents

Advertisement

WARNING – SERVICING TO BE CARRIED OUT ONLY BY AN AUTHORISED PERSON
Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.

Stick on Label

Stick the LP gas label over the natural gas part of the
appliance data label.

Pressure Testing

Connect the appliance to the gas supply.
Check the appliance is gas sound.
The gas pressure can be measured at one of the hotplate
injectors (not the wok burner).
Lift off a burner head. Fit the pressure gauge to the jet. Turn
on and light one of the other burners. Turn on and press in
the control knob for the burner with the pressure gauge
fitted.
The pressure should be 29 mbar for Butane and 37 mbar for
Propane. After checking the pressure, turn off the taps and
replace the burner head.
Reassemble burner top, making sure it is reassembled in the
correct way on the burner body.
Check operation of all the burners.
25

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Classic 90Toledo 90

Table of Contents