Technical Data - Rangemaster Classic 90 Dual Fuel User's Manual & Installation Instructions

Dual fuel
Hide thumbs Also See for Classic 90 Dual Fuel:
Table of Contents

Advertisement

10. Technical Data

THE COOKER IS CATEGORY: CatII 2H3+.
It is supplied set for group H natural gas. A conversion kit from NG to LP is available for the cooker.
INSTALLER: Please leave these instructions with the User.
DATA BADGE LOCATION: Cooker back, serial number repeater badge below oven door opening.
COUNTRY OF DESTIONATION: GB, IE.
Connections
See the appliance badge for test pressures.
Natural gas
Butane
Propane
Dimensions
Refer to 'Positioning the Cooker' .
Overall height
Overall width: Rangemaster and Toledo 90
Overall depth: Rangemaster and Toledo 90
Overall width: Classic 90
Overall depth: Classic 90
Minimum space above the hotplate
Ratings
Hotplate
Bypass Screw*
Wok burner
(Classic
& Toledo)
Large burner
Medium burner
Small burner
* The valves in this cooker are fitted with adjustable bypass screws. The cooker is supplied with the bypass screws set for
Natural gas. For LPG conversion the bypass screws must be screwed all the way down.
Oven Efficiency
Ovens
Maximum power output @ 230 V 50 Hz
Energy efficiency class on a scale of
A (more efficient) to G (less efficient)
Energy consumption based on standard load
Usable Volume (litres)
Size
Time to cook standard load
Surface area of the grid
Grill
Maximum total electrical load at 230 V (approximate total including oven lights, oven fan, etc.): 7.4 kW.
Gas (Rp ½ at rear right-hand side)
57
3.5 kW
40
3.0 kW
32
1.7 kW
28
1.0 kW
2.3 kW
20 mbar
29 mbar
37 mbar
minimum 905 mm
600 mm excluding handles; 650 mm including handles
608 mm excluding handles; 670 mm including handles
Natural Gas 20 mb
Injector
internal 78
external 126
134
109
75
Forced Air Convection
27
ArtNo.105-0008 - Technical data - 90 induction - Elan
Electric
230/400 V 50 Hz
maximum 930 mm
896 mm
900 mm
650 mm
L.P. Gas
3.5 kW (246 g/h)
3.0 kW (210 g/h)
1.7 kW (119 g/h)
1.0 kW (70 g/h)
Main Oven
Forced Air Convection
2.5 kW
A
0.90 kWh
69
Large
38 minutes
1400 cm
2
Injector
internal 53
external 82
87
68
51
Tall Oven
2.5 kW
A
0.99 kWh
66
Large
49 minutes
790 cm
2