WARNING – SERVICING TO BE CARRIED OUT ONLY BY AN AUTHORISED PERSON
Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.

8. Conversion to LP gas

Check the technical data section at the back of the book
that the hob is convertible to the gas you want to use.
A suitably competent person must perform the conversion.
After conversion the installation must comply with the
relevant regulations and also the local electricity supply
company requirements. Read the instructions before
converting this appliance.
Failure to convert the appliance correctly could
nn
invalidate any warranty or liability claims and lead to
prosecution.
When servicing or replacing gas-carrying components
disconnect from the gas supply before starting operation.
Check the appliance is gas sound after completion.
DO NOT use reconditioned or unauthorised gas controls.
Disconnect from the electricity supply before servicing.
Before electrical reconnection, check that the appliance is
electrically safe.

Injectors

Remove the burner caps and heads. Remove the old jets
(Fig.8-1). Fit the new jets (see Technical Data section at the back
of the book for correct jets). Reassemble in the reverse order.

Tap adjustment

Pull off all the control knobs and remove the handrail. Unscrew
the 2 cross-headed screws hidden behind the handrail end
brackets (Fig.8-2) and remove the 3 fixing screws underneath
the control panel (Fig.8-3).
The control panel will drop down slightly. It is held at the top
by two holes in the top edge, one at each end, that locate on
the tags on the inner panel. Lift the control panel clear of the
tags and pull forwards, taking care not to damage or strain the
wiring.
Using a screwdriver, tighten the bypass screw (Fig.8-4).

Stick on label

Stick the LP gas label over the natural gas part of the appliance
data label.

Pressure Testing

Connect the appliance to the gas supply. Check the appliance
is gas sound.
The gas pressure can be measured at one of the left hand
hotplate burner jets. Lift off a burner head. Fit the pressure
gauge to the jet. Turn on and light one of the other burners
with a match. Turn on and press in the control knob for the
burner with the pressure gauge fitted.
The pressure should be 29 mbar for Butane and 37 mbar for
Propane. After checking the pressure, turn off the taps and
replace the burner head.
Reassemble burner top, making sure it is reassembled in the
correct way on the burner body.
Check the appliance is gas sound.
Check operation of all the burners.
A
ArtNo.311-0010 Injectors
A – Jet, B – Internal injector, C – External injector
Art No 215-0028 - Handrail fascia fixings
ArtNo.270-0032 - 90 Prof+ FX - Removing the control panel
ArtNo.0102-0001 - Unscrewing
the control valve bypass screw
25
Fig.8-1
B
C
Fig.8-2
Fig.8-3
Fig.8-4

Advertisement