Sony DynaView SSC-CR441 Operating Instructions Manual page 12

Color video camera
Table of Contents

Advertisement

qa FUNCTION SWITCH
Adjust the following settings using the pin 1 to 16.
m
SW Pin No.
1-8
9-10
11
12
13
14-16
* The information in the table above is also found in "Baud rate / Indication / Terminal resistance /Interface Settings"
on page 66.
Note
In the factory default settings, the camera address switch is set to 0 and both the ALARM
OUT and POWER indicator switches are set to OFF.
12
Location and Function of Part
Function
Camera address switch
Communication baud rate
switch
ALARM OUT indicator
switch
POWER indicator switch
Termination switch
Communication standard
switch
Description
Set the camera address. For details, see "Camera
Address Settings" on page 57.
Set the communication baud rate between the
camera and keypad controller.
Settings for pin 9/10
OFF/OFF: 2400bps, ON/OFF: 4800bps, OFF/
ON: 9600bps, ON/ON: 19200bps
Turn the indicator on or off.
ON: The indicator lights up in orange while the
alarm function is set to on.
OFF: The indicator does not light up.
Turn the indicator on or off.
ON: The indicator lights up in green while the
power is turned on.
OFF: The indicator does not light up.
Set to ON when the unit is connected at the end
of an RS-485 or RS-422 connection. Set to OFF
if it is not connected at the end.
Set the communication standard between the
camera and keypad controller.
Pin 14
ON: RS-422 communication standard
OFF: RS-485 communication standard
Pin 15-16
ON (both Pin 15 and 16) : RS-485 (half-duplex)
communication standard
OFF (both Pin 15 and 16) : RS-485 (full-duplex)/
RS-422 communication standard

Advertisement