GAS PIPING
INSTALLATION

Gas Piping Installation

1. The installation must conform with local codes, or in the
absence of local codes with the National Fuel Gas Code,
ANSI Z223.1 or the CAN/CGA-B149, Installation Codes.
2. Check identification nameplate for type of gas for dryer.
3. Check the altitude of dryer.
4. Check with utilities company for proper gas pressure and gas
supply line.
5. Natural gas only—check the gas pressure inlet supply to
dryer, 11 inches (27 mbar) water column maximum. Manifold
pressure—3.5 inches (8.7 mbar) water column pressure.
6. L.P. gas only—manifold pressure—13 inches (32 mbar)
water column maximum.
CAUTION: Low gas pressure and intermittent gas will cause
gas ignition problems and inadequate drying of laundry.