VeNTING INSTALLATION
INTAKe/exhAuST MANIFOLD ReMOVAL
AND VeNT INSTALLATION
The intake/exhaust manifold is shipped attached to insert. It may
be removed to allow tight installation.
1. Unfasten the two (2) machine screws on the face of the unit
and release the plate assembly by sliding the plate back.
2. Attach the exhaust and the intake flex pipes to the collar on
the plates with a hose clamp (not provided) or other approved
methods (check local codes).
3. Re-attach exhaust baffle and manifold assembly in reverse
order of Step 1.
The unit is shipped from the factory as a natural gas unit
with the baffle installed. The baffle should be sufficient for
venting up to 20 feet (6 m) off the top of the unit. An extra
baffle plate is shipped with the unit for installations 20
feet and above. Adjust the plate to the closed position as
desired. Figure 10
20304164
Exhaust Collar
Machine
Screws
Figure 9
FP2979
intake exhaust
Bottom View
Closed position
Figure 10 -
Baffle Assembly and Adjustment
ICFDV Fireplace Insert
Intake Collar
Exhaust/Intake
Slide Plate
Assembly
FP2979
Loosen Four (4) Screws to Adjust
Bottom View
Open position
FP1961
baffle adjustment
9/08
13