pRODuCT FeATuReS

pRODuCT SpeCIFICATIONS
This appliance has been certified for use
with either natural or propane gas. Refer
to the appropriate data plates.
This appliance is not for use with solid
fuels.
The appliance is approved for bedroom or
bedsitting room installations.
The appliance must be installed in accor-
dance with local codes if any. If none exist
use the current installation code. ANSI
Z223.1/NFPA 54 in the USA, CSA B149
in Canada.
This appliance is mobile home appr-
oved.
The appliance must be properly connected
to a venting system.
The appliance is not approved for closet
or recessed installations.

hIGh eLeVATIONS

Input ratings are shown in BTU per hour and are certified
without deration for elevations up to 4,500 feet (1,370 m)
above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installation must be in accordance with the current
ANSI Z223.1/NFPA 54 and/or local codes having juris-
diction.
In Canada, please consult provincial and/or local authori-
ties having jurisdiction for installation at elevations above
4,500 feet (1,370 m).

GAS pReSSuReS

Inlet Minimum
Inlet Maximum
Manifold Pressure
20304164
FP2946
Figure 1 -
ICFDV Series Fireplace Insert Controls
Natural
Propane (LP)
4.5" w.c.
11.0" w.c.
10.5" w.c.
13.0" w.c.
3.5" w.c.
10.0" w.c.
Command
Center
FP2946
ICFDV insert controls
GAS SpeCIFICATIONS & ORIFICe SIZe
Max.Input Min. Input
Model
Fuel
ICFDV30LNTSC Nat.
ICFDV Fireplace Insert
AC Module
Control Board
Orifice
BTu/h
BTu/h
31,000
22,500
Gas
Valve
Size
#36
5