Additional R-22 Charge / Orifice Size For Various Matched Systems - 1 Phase - York H1RA018S06 Technical Manual

Split-system air conditioners 10 seer
Hide thumbs Also See for H1RA018S06:
Table of Contents

Advertisement

Additional R-22 Charge / Orifice Size for Various Matched Systems - 1 PHASE

ADDITIONAL R-22 CHARGE / ORIFICE SIZE FOR VARIOUS MATCHED SYSTEMS
Outdoor Unit
1
Unit Orifice (s)
Factory R-22 Charge, lbs-oz
Indoor Coil
Coil Orifice
G2FD024(S,H)14/17
61
G2FD030(S,H)17
65
G2FD035(S,H)14
65
G2FD036(S,H)17
75
G2FD036(S,H)21
75
G2FD042(S,H)21
78
G2FD046(S,H)17
78
G2FD048(S,H)21/24
78
G2FD060(S,H)24
90
G1HD024
59
G1HD036
69
G1HD048
81
G1HD060
93
G1FA/G1UA024S14/17
59
G1FA/G1UA030S14
65
G1FA/G1UA036S14
73
G1FA/G1UA03617/21
73
G1FA/G1UA048S17
84
G1FA/G1UA048S21
84
G1FA/G1UA060S24
90
G1NA024S17G
51
G1NA030S17H
57
G1NA030S17K
63
G1NA030S21B
57
G1NA030S21M
63
G1NA036S17J
67
G1NA036S21C
67
G1NA048S21D
78
G1NA048S24P
78
G1NA060S24T
87
G1NF024SOF
63
G1NF036SOF
67
G1NF048SOF
78
G1NF060SOF
87
F2RP/F2FP018
53
F2RC/F2FC024
61
F2RP/F2FP024
61
F2RP/F2FP030
65
F2RC/F2FC036
75
F2RP/F2FP036
75
F2RP/F2FP042
78
F2FP048
84
F2FP060
90
FOOTNOTES:
1. These orifices are packed in the customer packet of each outdoor unit.
2. These orifices are factory mounted in the flow control device of each indoor coil.
3. Systems matched with furnaces or air handlers not equipped with blower-off delays, may require blower Time Delay Kit #6918A5011.
PROCEDURES:
1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaportor and for 15 feet of interconnecting line
tubing.
2. Verify the orifice size and additional charge required for specific evaportor coil in the system using the above table.
3. Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in the table above.
4. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for
evaportor + adder for line set.
5. If the orifice in the evaportor was changed, verify the evaportor nameplate has been marked with the correct orifice size.
Unitary Products Group
H1RA018S06 H1RA024S06 H2RA030S06 H2RA036S06 H1RA042S06 H1RA048S06 H3RA060S06
51,53,55
59,61,63
3 - 6
3 - 11
2
53 + 14
59 + 6
53 + 23
59 + 8
53 + 23
59 + 8
59 + 12
55 + 6
61 + 1
63 + 7
55 + 3
59 + 0
53 + 14
59 + 6
59 + 4
59 + 4
51 + 0
57 + 0
57 + 0
3
57 + 0
51 + 0
55 + 3
55 + 6
61 + 0
61 + 2
67
71,73,75
3 - 14
3 - 15
System Orifice - Additional Charge, Oz
67 + 3
67 + 3
71 + 0
67 + 6
71 + 3
69 + 9
71 + 3
71 + 7
71 + 7
67 + 7
73 + 9
73 + 15
65 + 0
67 +4
73 + 0
67 + 2
73 + 0
75 + 11
75 + 11
63 + 4
63 + 4
67 + 7
67 + 7
3
63 + 4
3
67 + 7
67 + 2
71 + 0
67 + 8
73 + 4
73 + 8
036-21121-002 Rev. B (0103)
75,78,81
78,81,84,87
5 - 4
7 - 5
75 + 1
75 + 1
78 + 6
75 + 9
81 + 15
78 + 14
81 + 20
78 + 8
78 + 9
81 + 16
75 + 1
81 + 13
81 + 7
81 + 13
81 + 14
81 + 20
78 + 0
78 + 4
78 + 0
78 + 4
3
3
78 + 0
78 + 4
75 + 1
73 + 8
87 + 6
87 + 10
96
6 - 2
96 + 6
96 + 1
96 + 6
96 + 0
96 + 11
96 + 6
3