Cooling Performance Data Table - Model H1Ra076S (25,46) - York H1RA018S06 Technical Manual

Split-system air conditioners 10 seer
Hide thumbs Also See for H1RA018S06:
Table of Contents

Advertisement

COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO.
INDOOR COIL MODEL NO.
CONDENSER
ENTERING AIR
TEMPERATURE
75
85
95
105
115
125
NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature.
T.C.
Coil
G2FD090(S,H)35
1.00
Unitary Products Group
H1RA076S(25,46)
K4EV090
ID CFM
2100
ID DB (°F)
85
ID WB (°F)
72
T.C.
79.1
76.3
S.C.
48.8
48.6
K.W
5.98
5.90
T.C.
76.4
73.7
S.C.
47.9
47.6
K.W
6.53
6.42
T.C.
73.8
71.1
S.C.
47.1
46.7
K.W
7.08
6.94
T.C.
71.1
67.4
S.C.
46.4
45.4
K.W
7.84
7.70
T.C.
68.4
63.7
S.C.
45.4
44.1
K.W
8.59
8.46
T.C.
65.6
60.1
S.C.
44.5
42.7
K.W
9.35
9.21
S.C.
KW
0.99
1.01
80
70
85
67
57
72
73.9
82.0
48.1
55.4
5.84
6.28
70.6
79.1
46.8
54.7
6.37
6.86
67.2
76.1
45.4
54.0
6.90
7.43
62.6
73.1
43.7
53.1
7.61
8.21
58.0
70.0
42.0
52.0
8.32
8.97
53.4
67.0
40.2
51.0
9.02
9.74
036-21121-002 Rev. B (0103)
2600
80
70
85
67
57
72
79.2
76.9
84.9
55.3
54.7
62.0
6.18
6.15
6.58
76.3
73.4
81.7
54.4
53.5
61.5
6.74
6.70
7.18
73.5
69.9
78.4
53.6
52.4
60.9
7.30
7.26
7.79
69.7
65.2
75.1
52.2
50.5
59.8
8.08
7.99
8.57
67.0
60.4
71.7
51.9
48.5
58.6
8.80
8.71
9.36
64.3
55.7
68.4
51.6
46.5
57.5
9.51
9.43
10.14
3100
80
70
67
57
82.0
79.9
61.9
61.3
6.48
6.46
79.0
76.2
61.2
60.3
7.07
7.04
75.9
72.6
60.4
59.4
7.65
7.61
72.0
67.7
58.9
57.2
8.46
8.36
68.2
62.9
57.5
55.0
9.28
9.10
64.3
58.1
56.0
52.8
10.09
9.84
19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents