Download Print this page
York 036-21103-003 Technical Manual

York 036-21103-003 Technical Manual

Split-system air conditioners

Advertisement

Quick Links

TECHNICAL GUIDE
SPLIT-SYSTEM AIR CONDITIONERS
10 SEER 50 H
Z
H*RA018S78 THRU H*RA036S78 (1 PH)
H*RA036S50 THRU H*RA060S50 (3PH)
(1.5 THRU 5 NOMINAL TONS)
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
®
The HRA Series condensing unit is the outdoor part of a ver-
satile system of air conditioning. It is designed to be custom
matched with one of UPG's complete line of evaporator sec-
tions, each designed to serve a specific function. Matching
Air Handlers are available for upflow, downflow or horizontal
applications to provide a complete system. Electric Heaters
are available if required. Add-On coils are available for use
with upflow, downflow or horizontal furnaces and air handlers.
FEATURES
• QUALITY CONDENSER COILS - The coil is constructed
of enhanced copper tube and aluminum fins.
• COIL PROTECTION - Coils are protected from damage by
a polymer mesh applied between the coil face, and a PVC
coated steel coil guard.
• PROTECTED COMPRESSOR - The compressor is inter-
nally protected against high pressure and temperature.
This is accomplished by the simultaneous operation of
high pressure relief valve and a temperature sensor which
protects the compressor if undesirable operating condi-
tions occur. A liquid line filter-drier further protects the
compressor.
• DURABLE FINISH - Cabinet is made of pre-painted steel.
The pre-treated flat galvanized steel provides a better
paint to steel bond, which resists corrosion and rust creep.
Special primer formulas and matted-textured finish insure
less fading when exposed to sunlight.
• LOWER INSTALLED COST - Installation time and costs
are reduced by easy power and control wiring connections.
Discharge line heat exchanger knockouts are provided, if
required. Available in sweat connect models only. The unit
contains enough refrigerant for matching indoor coils and
15 feet of interconnecting piping. The small base dimen-
sion means less space is required on the ground or roof.
• TOP DISCHARGE - The warm air from the top mounted
fan is blown up away from the structure and any landscap-
ing. This allows compact location on multi-unit applica-
tions.
• LOW OPERATING SOUND LEVEL - The upward air flow
carries the normal operating noise up away from the living
area. The rigid top panel effectively isolates any motor
sound. Isolator mounted compressor and the rippled fins of
the condenser coil muffle the normal fan motor and com-
pressor operating sounds.
• LOW MAINTENANCE - Long life permanently lubricated
motor-bearings need no annual servicing.
• EASY SERVICE ACCESS - Fully exposed refrigerant con-
nections, a single panel covering the electrical controls
and the molex plug in the control box connecting the con-
denser fan, make for easy servicing of the unit.
• SECURED SERVICE VALVES - Secured re-usable ser-
vice valves are provided on both the liquid and vapor
sweat connections for ease of evacuating and charging.
• FACTORY TESTED - to verify system operation and con-
trol functioning before shipment.
036-21103-003 Rev. A (0403)

Advertisement

loading

Summary of Contents for York 036-21103-003

  • Page 1 (1.5 THRU 5 NOMINAL TONS) Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at www.york.com for the most up-to-date technical information. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE DESCRIPTION ®...
  • Page 2 036-21103-003 Rev. A (0403) PHYSICAL AND ELECTRICAL DATA - 1 & 3 Phase MODEL H1RA018S78 H1RA024S78 H1RA030S78 H1RA036S78 H1RA036S50 H1RA048S50 H1RA060S50 Unit Supply Voltage Normal Voltage Range Minimum Circuit Ampacity Max. Qvercurrent Device Amps Compressor Type Recip Rated Load Compressor Amps...
  • Page 3 1900 1 PHASE HRA / FRP (SINGLE PHASE) 1000 1250 3 PHASE HRA / FRP (SINGLE PHASE) 1200 1600 1900 036-21103-003 Rev. A (0403) 036S78 036S50 048S50 4 - 11 7 - 10 9 - 12 71 + 0 71 + 0...
  • Page 4: Cooling Performance

    036-21103-003 Rev. A (0403) COOLING PERFORMANCE SUCT. T/P @ COMPR. MODEL TEMP. PSIG 61.5 68.5 H1RA018S78 76.0 84.0 61.5 68.5 H1RA024S78 76.0 84.0 61.5 68.5 H1RA030S78 76.0 84.0 61.5 68.5 H1RA036S78 76.0 84.0 61.5 68.5 H1RA036S50 76.0 84.0 61.5 68.5 H1RA048S50 76.0...
  • Page 5: Sound Ratings

    Unitary Products Group SOUND RATINGS UNIT MODEL MINIMUM 18” SERVICE ACCESS CLEARANCE ON ONE SIDE WEATHERPROOF DISCONNECT SWITCH CONTROL ACCESS PANEL 036-21103-003 Rev. A (0403) SOUND RATINGS DECIBELS THERMOSTAT TO FURNACE OR AIR HANDLER TERMINAL BLOCK NEC CLASS 1 WIRING...
  • Page 6: Condensing Unit

    036-21103-003 Rev. A (0403) TYPICAL FIELD WIRING - 1 PH APPLICATION (018S78 - 036S78) ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES POWER WIRING 230-1-50 CONTACTOR TERMINALS GND. COIL CONDENSING UNIT ALL OUTDOOR WIRING MUST BE WEATHERPROOF. USE COPPER CONDUCTORS ONLY.
  • Page 7: Cooling Performance Data

    1.90 2.18 13.0 11.1 13.7 11.1 2.11 2.04 1.98 2.28 T.C. S.C. 1.00 1.00 1.00 1.00 1.00 1.00 036-21103-003 Rev. A (0403) 18.2 17.2 18.4 18.3 11.6 11.9 11.4 12.4 1.71 1.69 1.68 1.67 17.5 16.1 18.2 17.8 11.7 11.6 12.0...
  • Page 8 036-21103-003 Rev. A (0403) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. IDCFM CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
  • Page 9 12.4 11.4 15.4 3.13 3.02 2.93 3.30 T.C. S.C. 1.00 1.00 1.00 1.02 1.03 1.03 1.02 1.03 1.03 036-21103-003 Rev. A (0403) 1050 25.7 24.6 26.7 26.1 16.7 16.8 16.9 17.8 2.49 2.46 2.56 2.53 24.6 22.8 26.1 25.2 16.6 16.2...
  • Page 10 036-21103-003 Rev. A (0403) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. IDCFM CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
  • Page 11 19.6 26.2 20.3 18.8 17.4 22.3 4.29 4.12 3.99 4.65 T.C. S.C. 1.00 1.00 1.00 1.02 1.02 1.01 036-21103-003 Rev. A (0403) 1250 1450 34.7 35.6 39.4 32.5 24.8 24.8 25.4 26.1 3.54 3.50 3.48 3.43 34.1 32.6 38.1 33.4 25.2...
  • Page 12 036-21103-003 Rev. A (0403) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. IDCFM CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
  • Page 13 40.4 54.2 38.7 36.7 32.8 42.0 7.31 7.09 6.84 7.78 T.C. S.C. 1.00 1.00 1.00 1.00 1.00 1.00 036-21103-003 Rev. A (0403) 1900 2150 62.8 60.0 66.6 63.3 44.0 43.6 47.5 46.5 5.76 5.69 5.62 5.56 61.4 57.5 65.4 62.1 43.7...
  • Page 14 036-21103-003 Rev. A (0403) MATCHING INDOOR COMPNENTS ADD-ON COILS - FOR FURNACE APPLICATION N1AH MODULAR BLOWER G2FD* COIL G2FD* MULTI-POSITION (UPFLOW, HORIZONTAL AND DOWNFLOW) AIR HANDLERS F2RP FAN COIL UNITS (UPFLOW, HORIZONTAL) P6UH FURNACE Unitary Products Group...
  • Page 15 036-21103-003 Rev. A (0403) NOTES Unitary Products Group...
  • Page 16 Subject to change without notice. Printed in U.S.A. Copyright © by York International Corp. 2003. All rights reserved. Unitary Product Group Supersedes: 036-21103-002 Rev. A (1101) 5005 York Drive 036-21103-003 Rev. A (0403) Norman 73069...