Additional R-410A Charge / Orifice Size for Various Matched Systems
Outdoor Unit
1
Required Orifice or TXV
Factory Charge, lbs-oz
2,3,4
Indoor Coil
FC/MC/PC24A3X
FC/MC/PC24B3X
FC/MC/PC30A3X
FC/MC/PC30B3X
FC/MC/PC32A3X
FC/MC/PC35B3X
FC/MC/PC35C3X
FC/MC/PC36A3X
FC/MC/PC36B3X
FC/MC/PC36C3X
FC/MC/PC37A3X
FC/MC/PC43B3X
FC/MC/PC43C3X
FC/MC/PC48C3X
FC/MC/PC48D3X
FC/MC/PC60D3X
FC/MC62D3X
UC24A3X
UC24B3X
UC30A3X
UC30B3X
UC36A3X
UC36B3X
UC36C3X
UC42B3X
UC42C3X
UC48C3X
UC48D3X
UC60C3X
UC60D3X
HC18A3X
HC30A3X
HC36B3X
HC42C3X
HC60D3X
HD24*3X
HD36*3X
HD48*3X
HD60*3X
AHP18B3X
AHP24B3X
AHP30B3X
AHP36C3X
AHP42C3X
AHP/SHP60D3X
AV24B3X
AV36C3X
AV/SV48D3X
AV/SV60D3X
For notes see Page 4.
Johnson Controls Unitary Products
YCJF24S41S1
YCJF30S41S1
1TVM(902/4F1)
1TVM(903/4G1)
3 - 2
3 - 7
5
–
5
–
12
2
12
2
16
10
16
10
16
10
8
4
8
4
8
4
24
19
24
19
24
19
40
32
40
32
–
–
–
–
8
–
8
–
8
4
8
4
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
10
–
16
11
25
19
–
–
16
–
18
–
51
42
–
–
–
–
3
–
16
–
19
–
–
–
–
3
–
25
19
–
–
–
–
YCJF36S41S1
YCJF42S41S1
1TVM(903/4G1)
1TVM(903/4G1)
3 - 10
4 - 4
Additional Charge, Oz
–
–
–
–
–
–
–
–
–
–
8
–
8
–
1
–
1
–
1
–
15
–
15
5
15
5
15
17
27
17
–
17
–
25
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
12
–
12
–
–
–
–
–
8
–
15
6
–
0
–
–
–
–
36
24
–
–
–
–
–
–
–
–
15
–
–
–
–
–
–
–
15
–
9
0
–
0
413437-YTG-C-0908
YCJF48S41S1
YCJF60S41S1
1TVM(905/4J1)
1TVM(906/4K1)
4 - 9
5 - 9
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
16
–
16
–
16
0
26
18
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
0
0
–
–
–
–
25
–
24
–
–
–
–
–
–
–
–
–
–
–
1
–
–
–
–
–
1
–
1
0
3