System Charge For Various Matched Systems - York LX Series Technical Manual

14 seer r-410a 1 phase 1.5 thru 5 nominal tons
Hide thumbs Also See for LX Series:
Table of Contents

Advertisement

5495499-YTG-B-0219

SYSTEM CHARGE FOR VARIOUS MATCHED SYSTEMS

Outdoor Unit
YFE18B21S
1,2
BA1 or BH1
Required TXV
3,4,5
Indoor Unit
AP18B
AP24B
AP30B
AP36B
AP36C
AP42C
AP48(C,D)
AP60(C,D)
AE18B
AE24B
AE30B
AE36(B,C)
AE42C
AE48(C,D)
AE60C
AE60D
AVC18B
AVC24B
AVC30B
AVC36(B,C)
AVC42C
AVC48(C,D)
AVC60C
AVC60D
CF/CM/CU18(A,B)
CF/CM/CU24(A,B)
CF/CM/CU30(A,B,C)
CF/CM/CU36(A,B,C,D)
CF/CM/CU42(B,C,D)
CF/CM/CU48(C,D)
CF/CM/CU60(C,D)
CF/CM64D
Some of the combinations shown in the above System Charge table require Advanced Main Air Circulating Fan indoor product. For approved coil
only matches, please see the "COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils" table.
FOOTNOTES:
1. For applications requiring a TXV, use S1-1TVM*** series kit.
2. A TXV kit must be used with these indoor units to obtain system performance.
3. Systems matched with furnaces or air handlers not equipped with blower-off delays may require 60 second time delay.
4. CF coils cannot be used in horizontal applications.
5. Charge adders shown above do not indicate that coils are rated for every application. Refer to Performance Data Tables for actual performance for specified sys-
tem matches. Obtain certified system ratings from www.ahridirectory.org.
CHARGING PROCEDURES:
1. Check the Factory Unit Charge listed on the unit nameplate to verify the refrigerant charge for the outdoor unit, the smallest matched indoor unit, and the 15 feet
of interconnecting lineset.
2. Verify the indoor metering device and additional charge required for the specific matched indoor unit in the system using the above table.
3. Add additional charge for the amount of interconnecting lineset greater than 15 feet at the rate specified in the Physical and Electrical Table.
4. For installations requiring additional charge, weigh in refrigerant for the specific matching indoor unit and actual lineset length.
5. Once the charge adders for matched indoor unit and for lineset have been weighed in, verify the system operation against the temperatures and pressures in the
Charging Chart for the outdoor unit. Locate Charging Charts on the outdoor unit and also in the Service Data Application Guide on
www.simplygettingthejobdone.com. Follow the Subcool or the Superheat charging procedure in the Installation Manual according to the type of indoor metering
device in the system, and allow ten minutes after each charge adjustment for the system operation to stabilize. Record the charge adjustment made to match the
Charging Chart.
6. Permanently stamp the unit data plate with the TOTAL SYSTEM CHARGE defined as follows: TOTAL SYSTEM CHARGE = Base Charge (as shipped) + charge
adder for matched indoor unit + charge adder for actual lineset length + charge adjustments to match the Charging Chart.
4
YFE24B21S
YFE30B21S
BA1 or BH1
0
3
0
10
7
10
7
11
11
0
3
0
8
5
10
7
0
3
0
8
5
10
7
0
3
0
8
5
10
7
11
YFE36B21S
BB1
BC1 or BA1
Additional Charge, oz
2
2
0
2
2
2
2
5
0
2
0
5
5
0
2
0
5
5
0
2
0
2
2
5
YFE42B21S
YFE48B21S
BC1
BC1
0
2
0
9
2
2
2
0
9
2
29
22
2
2
0
9
2
29
22
0
2
0
9
2
29
22
Johnson Controls Ducted Systems
YFE60B21S
BD1
0
0
20
0
20
0
20