When The Register Does Not Operate At All - Casio TE-7000S User Manual

Hide thumbs Also See for TE-7000S:
Table of Contents

Advertisement

Troubleshooting

When the register does not operate at all

Perform the following check whenever the cash register enter an error condition as soon as you switch it on. The
results of this check are required by service personnel, so be sure to perform this check before you contact a
CASIO representative for servicing.
Start
Is register plugged in?
Is power on?
Do figures appear on the display?
Do keys function?
Does paper feed?
TE-7000S User's Manual
Plug in the power cord.
Press <DISP ON/OFF> for a few seconds.
Is the electrical outlet active?
Contact CASIO service
representative.
Is the mode position correct?
Contact CASIO service
representative.
Is paper loaded correctly?
Is the platen arm closed correctly?
Contact CASIO service
representative.
YES
N O
Use other outlet.
Set to correct position.
Load paper.
Set platen arm correctly.
www.cashregisters.net
101
E

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents