Vent Requirements - Jøtul GF 300 BV Allagash Installation And Operation Instructions Manual

Natural vent gas stove
Table of Contents

Advertisement

137945_Rev_F 7.29.10
Approved B-Vent Configurations
Listed B-Vent Termi-
nation Cap required.
NOTE:
Installation at
altitude greater
than 2000' re-
quires minimum
12 ft. vertical rise
from Draft Hood.
Figure 7.
Listed B-Vent
termination cap
NOTE:
Installation at
altitude greater
than 2000' re-
quires minimum
12 ft. vertical rise
from Draft Hood.
Figure 9.
10
Maximum
chimney
height off
Draft Hood is
35 feet.
Minimum
chimney
height off
Draft Hood is
7 feet.
required.
Maximum
chimney
height off
Draft Hood is
35 feet.
Minimum
chimney
height off
Draft Hood is
7 feet.
Maximum
total horizontal
anywhere in
venting configu-
ration
is 4 feet.
Maximum
NOTE:
total horizontal
Installation at
anywhere in
altitude greater
venting configu-
than 2000' re-
quires minimum
is 4 feet.
12 ft. vertical rise
from Draft Hood.
Figure 8.
total horizontal
venting configu-
NOTE:
Installation at
altitude greater
than 2000' re-
quires minimum
12 ft. vertical rise
from Draft Hood.
Figure 10.
Listed B-Vent
Termination
Cap required.
ration
Minimum chimney
height from Draft
Hood
is 7 feet.
Max. Four, 45°
or Three, 90°
Elbows
Listed B-Vent
Maximum
termination
cap required.
anywhere in
ration
is 4 feet.
Minimum chimney
height from Draft
Hood
is 7 feet.
Max. Four, 45°
or Three, 90°
Elbows