Fireplace Requirements

Figure 2 shows the minimum size requirements for the type of fireplace used.
Minimum Fireplace Size
e
Depth
f
Width (front)
g
Width (rear)
h
Height (front)

Fireplace Altered Tag

Attach the "This fireplace has been altered..." plate to the fireplace (use two screws or other suitable
method). You may wish to place it in a location where it will be covered by the surround panels.

Hearth Requirements

Non-combustible hearth must extend 12" (300mm) in front of the insert and 4.625" (118mm) from
both sides of the insert
When installed over a timber floor:
Hearth must be a minimum of 75mm of non-
combustible masonry with 16mm of FC sheet
along with offcuts to provide air flow (see
illustration to the right).
When installed over a cement floor:
Hearth must be non-combustible.
© Travis Industries
Installation
(for qualified installers only)
Masonry Fireplace
15.75" 420mm
29.25" 760mm
29.25" 760mm
21.75" 570mm
100-01279
Figure 2