Appendix A - Alternate Floor Protection - Jøtul F 400 USA Installation And Operating Instructions Manual

Table of Contents

Advertisement

USA/Canada
Part list for the Jøtul F 400 woodstove
Consult your dealer for part numbers and replacement parts.
No.
Description
1
Ashlip Packed
2
Handle Ash Door Compl.
3
Latch
4
Spring for Latch
5
Nut Hex.
6
Screw
7
Gasket L=1020
8
Wooden Knob Ash House
9
Screw Hex.
10
Side Right
11
Washer
12
Screw Hex Cap Flange Frame
13
SD Front
14
Gasket top plate, L=1840
15
Screw Hex. Cap Flange Frame
16
Ash Door
17
Top Plate
18
Nut Hex. Cap Flange
19
Gasket Upper Back Plate, L=835
20
Back Plate Upper Compl.
21
Gasket , L=930
22
Screw Hex. Selftr.
23
Smoke Outlet Compl.
24
Screw Machine Oval Poz Blackcr.
25
Rivet Gesipa
26
Back Plate Lower Compl.
28
Side Left
29
Leg
30
Screw Hex. Cap Flange Frame
31
Screw Hex.
32
Bottom Upper
33
Gasket for Burn Plate , L=180
33
Gasket , L=180
34
Burn Plate Right Compl.
35
Secondary Air Chamber
36
Gasket , L=1200
37
Gasket , L=820
38
Air Deflector
39
Secondary Air Chamber Compl.
40
Baffle Plate II
41
Screw Hex.
42
Heat Shield Underneath, EU
43
Inspection Cover EU
44
Burnplate Back
45
Brick Refactory
46
Fire Grate
47
Burn Plate Left Compl.
48
Screw Hex. Cap Flange Frame
49
Screw Hex. Cap Flange Frame
50
Bottom Lower
51
Screw Hex. Cap Flange Frame
52
Hinge Bolt for Ash Door
53
Ash Pan
54
Ash House Compl.
55
Sliding Vent
56
Air Divider
57
Rivet
58
Sleeve
59
Handle Air Setting
61
Single Door Compl w/o Glass
62
Glass Clip
63
Gasket for Glass
64
Gasket for Door
65
Screw Panh.
66
SD Glass
67
Latch Bolt
68
Washer
69
Spring Pin
70
Washer
71
Latch
72
Latch Compl. w\Wooden Knob
73
Wooden Knob
74
Gasket Ash House
75
Adapter Outside Air
77
Fire Screen
18
9.0 Appendix A
Alternate floor protection
All floor protection materials must be non-combustible ie. metal,
brick, stone, mineral fiber boards). Any combustible material
may not be used.
The easiest means of determining if a proposed alternate floor
material meets requirements listed in this manual is to follow
this procedure.
R-value = thermal resistance
k-value = thermal conductivity
C-value = thermal conductance
1. Convert the specification to R-value;
a. If R-value is given, no conversion is needed.
b. If k-value is given with a required thickness (T) in inches:
R=1/k X T.
c.
If C-value is given: R=1/C.
2. Determine the R-value of the proposed alternate floor protector.
a. Use the formula in Step 1 to convert values not expressed
as "R".
b. For multiple layers, add R-values of each layer to determine
overall R-value.
3. If the overall R-value of the sustem is greater than the R-value
of the specified floor protector, the alternate is acceptable.
Example:
The specified floor protector should be 3/4" thick material with a
k-factor of 0.84. The proposed alternate is 4" brick with a C-factor
of 1.25 over 1/8" mineral board with a k-factor of 0.29.
Step A. Use formula above to convert specifications to R-value.
R=1/k X T= 1/.84 X .75 = .893
Step B. Calculate R of proposed system.
4" brick of C-1.25, therefore
R brick = 1/C = 1/1.25 = 0.80.
1/8" mineral board of k = 0.29 therefore
R mineral board = 1/.29 X 0.125 = 0.431
Total R = R brick + R mineral board=
0.8 + 0.431=1.231
Step C. Compare proposed system R = 1.231 to specified R of 0.893.
Since R is greater than required, the system is acceptable.
Definitions:
Thermal conductance =
C =
Btu
=
(hr)(ft
2
)(F)
Thermal conductivity =
k =
Btu
=
(hr)(ft
2
)(F)
Thermal resistance=
R =
Btu
=
2
(hr)(ft
)(F)
W
(m
2
)(K)
W
=
(Btu)
(m
2
)(K)
(hr)(ft)(F)
(m
2
)(K)
=
(Btu)(inch)
2
W
(hr)(ft
)(F)