Turntable Motor - GE Advantium PSA1200R Technical Service Manual

Advantium 120 v (atc)
Hide thumbs Also See for Advantium PSA1200R:
Table of Contents

Advertisement

Turntable Motor

Location (See
Bottom View
120 VAC
Approximately 2.6 K Ω.
Troubleshooting
1. Disconnect power to the oven.
2. Pivot the Control Panel Assembly out from the
oven. (See
Control Panel Removal
3. To gain better access to components, remove
the wires that plug into the large relays on the
Relay Board. (See
Relay Board
that the Smart Board CN103 wire harness (See
.) is routed through.
Smart Board
4. Check voltage between either side of the Bottom
TCO and Relay Board connector CN6 pin 3.
• If 120 VAC is present, problem is with
Turntable Motor, Primary Interlock Switch, or
wiring to motor.
• If 120 VAC is not present, the Turntable
motor relay on the Relay Board is not
closing. (See
Relay Board,
section.)
.)
.)
.) Cut the wire tie
troubleshooting
– 61 –
Disassembly
To remove the Turntable Motor:
1. Remove the turntable, turntable support, and
the Bottom Cover.
2. Remove the 2 Phillips-head screws.
Note
When replacing the Turntable Motor, be sure the
RF gasket is positioned over the motor shaft and
between the motor and motor plate, as shown
below.
When replacing the turntable support, ensure
it is fully seated into the "D" shaped shaft of the
Turntable Motor and is fl ush with the oven fl oor.
RF Gasket
Disconnect
Motor Plate
RF Gasket