Magnetron - GE Advantium PSA1200R Technical Service Manual

Advantium 120 v (atc)
Hide thumbs Also See for Advantium PSA1200R:
Table of Contents

Advertisement

Magnetron

Location (See
Right Side View
Filament resistance less than 1 Ω.
The Magnetron converts the high voltage
supplied by the transformer, capacitor,
and diode into radio frequency waves of
electromagnetic cooking energy.
WARNING: Always be certain the capacitor
is discharged before servicing. (See
) Use electrician's discharge pliers
and Diode.
and electrician's gloves under Kevlar gloves (or
equivalent protective gloves) when discharging
the capacitor.
Note: The capacitor has an internal discharge
resistor that automatically discharges the
capacitor when the oven turns off. Under normal
operation, the capacitor should fully discharge
within 30 seconds.
For operating algorithms, see High Voltage in
the
Load Algorithm Chart
Disassembly. (See
Disassembly
Troubleshooting
1. Does the display operate properly?
• If no, see
VFD Board
• If yes, go to step 2.
2. Is Magnetron staying on all the time or not
coming on?
• If Magnetron is staying on, go to step 8.
• If Magnetron is not coming on, go to step 3.
.)
Capacitor
.
.)
, troubleshooting step 1.
– 63 –
3. Pivot the Control Panel Assembly out from the
oven. (See
Control Panel
4. To gain better access to components, remove
the wires that plug into the large relays on the
Relay Board. (See
Relay Board
that the Smart Board CN103 wire harness (See
.) is routed through.
Smart Board
5. Set oven to Microwave for 2 minutes. (See
for set up instructions.)
Operating Modes
6. Start Microwave cycle. While unit is running,
check resistance between the 2 terminals on
Relay Board RY14. Note: This step requires
checking resistance of relay contacts while the
unit is running. The high voltage relay wires
(RY14) must not be connected to the relay when
making this check.
• If resistance is infi nite, the high voltage
relay is not closing. (See
troubleshooting section.)
• If resistance is approximately 0 Ω, go to step 7.
7. Check voltage between the primary leads of the
High Voltage Transformer.
• If 120 VAC is present, problem is with one
or more of the high-voltage components.
Check resistance of the magnetron
fi lament. If OK, see
troubleshooting section, see
troubleshooting section.
Diode,
• If 120 VAC is not present, see
troubleshooting step 4.
Interlock Switch,
8. Disconnect Relay Board RY14. Is the Magnetron
staying on?
• If the Magnetron turns off, the magnetron
relay is stuck closed. (See
troubleshooting section.)
• If Magnetron stays on, the single wire in the
connector that connects to RY14 is shorted
to ground.
.)
.) Cut the wire tie
Relay Board,
High Voltage Transformer,
Capacitor and
Primary
Relay Board,
(Continued Next Page)