Clearances & Height Requirements - Monessen Hearth AVFL Series Installation & Operating Instructions Manual

Vent free fireplace system
Hide thumbs Also See for AVFL Series:
Table of Contents

Advertisement

AVFL Vent Free Fireplace
CLEARANCES AND HEIGHT REQUIREMENTS
Ensure that minimum clearances shown in Figures 4 and
5 are maintained. Left and right clearances are determined
when facing the front of the firebox.
Follow these instructions carefully to ensure safe instal-
lation. Failure to follow these requirements may create a
fire hazard.
Sidewall Clearances — The clearance from the inside of
the appliance to any combustible adjacent wall should not
be less than 6". Figure 4
Ceiling Clearance — The ceiling must be at least 36" from
the firebox opening. Figure 4
Back Wall Clearance — The appliance may be placed
against a combustible back wall.
36
Minimum
"
From Opening
12
Max.
"
Depth
6
Min.
"
Figure 4 –
Sidewall and Ceiling Clearances
FP3006
mantel clearances
Monessen • AVFL42 Installation Instructions • 4117-900 Rev. B • 05/20
10
The dimensions shown in Figures 4 and
5 are minimum clearances to maintain
when installing this heater. Left and right
clearances are determined when facing the
front of the heater.
Follow these instructions carefully to
ensure safe installation. Failure to follow
instructions exactly can create a fire
hazard.
Floor Clearance — The fireplace may be installed directly
on a combustible floor or a raised platform of an appropriate
height. Do not place fireplace on carpeting, vinyl, tile or
other soft floor coverings. It may, however, be placed on flat
wood, plywood, particle board or other hard surfaces. Be
sure fireplace rests on a solid continuous floor or platform
with appropriate framing for support so that no cold air can
enter from under the firebox. See note below regarding
floor installation with wide contemporary faces.
Mantel clearances — Must meet the clearance require-
ments detailed in Figures 4 and 5.
SIDE VIEW
2
/
Max
1
"
2
Depth
28
Min.
"
From Opening
18
Min.
"
From Opening
FP3006
TOP VIEW
Figure 5 –
Mantel Clearances
PRE-INSTALLATION INFORMATION
Wall
12"
6"
2
/
"
1
28"
2
23"
18"
Top of Fireplace
Opening
FP3007
mantel clearances
1"
1¹⁄₂"
Fireplace
2¹⁄₂"
Opening
3"
5"
6"
FP3008
mantel leg
Stud
Insulation
Board
Standoff
FP3007
3¹⁄₂"
4¹⁄₂"
45°
FP3008