Bypass/Unbypass Device - Bosch IUI-MAP0001 User Manual

Map control center
Table of Contents

Advertisement

MAP Control Center
Figure 2.58 View Device Status Detail screen
2.7.3

Bypass/Unbypass Device

To arm the system, regardless of a particular device's status, the user can bypass that device.
NOTICE!
A device cannot be bypassed if the area containing the device is armed, there is an active
event in the system from the area containing the device, or if the device is in Walk Test.
For example, if a window contact is installed on a window that the user wants to leave open,
the user can bypass that window contact point. This allows the user to arm the system even
though the window contact point's status is Active.
NOTICE!
Bypassing a device only disables the device's ability to notify the security system of an alarm
or trouble event. Tamper events are still active in a bypassed device.
From the Status menu (Figure 2.45, Page 32), press Bypass/Unbypass Device. The Bypass/
Unbypass Device screen (Figure 2.59, Page 37) lists the devices and displays whether each
device is either:
Press a device's on-screen button to change its bypass status.
Figure 2.59 Bypass/Unbypass Device screen
Bosch Security Systems, Inc.
Bypassed (
), or
Unbypassed (
).
User guide
Operation | en
37
F.01U.168.328 | 03 | 2011.05