Electrical Connections; Tool Specifications - King Canada Tru-Cut 8380 Instruction Manual

10” compound sliding miter saw with twin laser guide
Table of Contents

Advertisement

ALL ELECTRICAL CONNECTIONS MUST BE DONE BY A QUALIFIED ELECTRICIAN. FAILURE TO COMPLY MAY RESULT IN
SERIOUS INJURY! ALL ADJUSTMENTS OR REPAIRS MUST BE DONE WITH THE MITER SAW DISCONNECTED FROM THE
POWER SOURCE. FAILURE TO COMPLY MAY RESULT IN SERIOUS INJURY!
POWER SUPPLY
WARNING: YOUR MITER SAW MUST BE CONNECTED TO A 110V,
15-AMP. BRANCH CIRCUIT. FAILURE TO CONNECT IN THIS WAY
CAN RESULT IN INJURY FROM SHOCK OR FIRE.
110V OPERATION
As received from the factory, your miter saw is ready to run for 110V
operation. This miter saw is intended for use on a circuit that has an
outlet and a plug which looks like the one illustrated in Fig.1.
EXTENSION CORDS
The use of any extension cord will cause some loss of power. Use the
following table to determine the minimum wire size (A.W.G-American
Wire Gauge) extension cord. Use only extension cords which accept
the tool's plug.
For circuits that are further away from the electrical circuit box, the wire
size must be increased proportionately in order to deliver ample voltage
to the motor. Refer to Fig.2 for wire length and size.
Model ..............................................................................................................................................................................................8380
Voltage ............................................................................................................................................................................................110V
Input power ................................................................................................................................................................................15 Amp.
No load speed ......................................................................................................................................................................5,200 RPM
Blade size..........................................................................................................................................................................10" x 40 teeth
Arbor size ..........................................................................................................................................................................................5/8"
Miter table angles ............................................................................................................................0
Crosscut 90
0
..........................................................................................................................................................................3" x 13-3/4"
Miter 45
0
(right & left) ..............................................................................................................................................................3" x 9-3/8"
Bevel 45
0
(left) ......................................................................................................................................................................2" x 13-3/4"
Compound (Miter & Bevel 45

ELECTRICAL CONNECTIONS

TOOL SPECIFICATIONS

0
left) ........................................................................................................................................2" x 9-3/8"
WARNING!
110V GROUNDED OUTLET
CURRANT
CARRYING
PRONGS
GROUNDING
PLUG
LENGTH OF
CONDUCTOR
0-25 FEET
26-50 FEET
51-100 FEET
FIGURE 1
WIRE SIZES REQUIRED
(AMERICAN WIRE GAUGE)
110V LINES
NO.12
NO.12
NO.10
FIGURE 2
0
, 15
0
, 22.5
0
, 30
0
, 45
0
left and right