Wiring Diagram - Travis Industries Lopi GreenField GS Owner's Manual

Direct vent freestanding stove
Table of Contents

Advertisement

Maintenance
42

Wiring Diagram

Caution:
Label all wires prior to disconnection when servicing controls. Wiring errors can cause
improper and dangerous operation. Verify proper operation after servicing.
Accent Light
Rheostat
120 VAC
Power In
© Travis Industries
Spark Rod
Accent
Light (s)
Pilot Ground
Optional
Blower
Hookup
Comfort Control
Valve
AC
ADAPTER
Green
Orange
Yellow / Green
CONTINUOUS
PILOT
INTERMITTENT
PILOT
(for qualified service personnel only)
Pilot
Sensor
IPI / CPI
Blue
White
COMFORT
CONTROL
4101028
CN4
PILOT
DIGITAL
SENSOR
FIREPLACE
CN0
BURNER
CONTROL
SPARK ROD
DIAGNOSTIC
VALVE
COMMAND
POWER
GROUND
CN3
CN2
POWER SUPPLY
Red
Green
Black
Red
White
Red
Black
AA
BATTERY
TRAY
100-01255_000
CN1
MAIN BURNER

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents