Closing The Diffuser - Travis Industries Lopi GreenField GS Owner's Manual

Direct vent freestanding stove
Table of Contents

Advertisement

16
Closing the Diffuser (for top vent configurations only)
IMPORTANT NOTE: The diffuser can be easily closed with no vent in place. Consult the vent
configuration charts to determine diffuser position. If the diffuser needs to be in the closed position,
adjust the diffuser prior to installing vent.
To close the diffuser, reach into the vent starter section and bend the diffuser back (see photos
below). You may need a screwdriver to bend the upper portion of the diffuser 90° (see photos
below).
Diffuser Open (stock)
Closing the Diffuser After Vent is Installed
The diffuser may be removed from within the firebox and bent into the closed position . This
requires removal of the burner, fireback shelf, and rear firebox wall (rivet cover). Once removed,
the diffuser may be removed from below, bent 90°, and re-installed. See the illustration below.
Inner flue assembly
© Travis Industries
Installation
The diffuser is found on the inner flue assembly
(see Top to Rear Vent Configuration for details).
Bottom of inner
flue assembly
(for qualified installers only)
Bend the round portion of the
diffuser so it is bent (position # 2).
DIFFUSER SIDE VIEW
Before (Stock - Position # 1)
a
After (Position # 2)
Remove the
diffuser.
4101028
Diffuser Closed
b
Replace the
diffuser.
100-01255_000
c

Hide quick links:

Advertisement

Table of Contents
loading