EN
 
7.3.6
Heat quantity function
The controller has a function for measuring the quantity of heat.
This allows, for instance, to record the quantity of heat fed into the
storage tank from the solar energy system. To do this, the tempera-
ture of the supply and return, and the flow rate of the solar energy
system must be recorded. The flow rate can be read in via a pulse
generator, recorded via a special Direct Sensor, or approximately cal-
culated by means of the pump speed. Since the heat quantity depends
on the proportion of glycol in the fluid, this also is accounted for in the
calculations. From these values, the controller determines the quantity
of heat and shows this in the display.
NOTE
When using the Direct Sensor, observe the manufacturer's technical data.
Setting the flow rate determination and the glycol
proportion
"Functions" submenu selected, see "Selecting a function"
(see chapter 7.3.1).
Heat quantity activated, see "Activating a function" (chapter 7.3.1).
: press button.
 
The display for setting the flow rate determination method and
the glycol proportion appears.
SET: press button.
The flow rate determination method flashes in the display.
: choose between "Pulse generator", use of a "Direct Sensor", or
"Without flow sensor".
SET: press button to confirm.
The pulse value (if "Pulse generator" is selected) or sensor type (if
"Direct Sensor" is selected) flashes in the display.
: enter the value or type for the selected flow rate sensor.
for "Pulse generator", see chapter 14.3 "Parameter values for func-
tions"
for "Direct Sensor", enter the sensor type
for "Without flow sensor", this step is dispensed with
SET: confirm the value.
"Glycol proportion" flashes in the display.
: set the value.
SET: press button to confirm.
The settings are saved.
Allocating inputs for temperature sensors
: press button.
 
The display for setting the temperature inputs appears.
SET: press button.
"T" flashes in the display (input for supply temperature).
: choose the desired input.
SET: press button to confirm.
"T" flashes in the display (input for return temperature).
: choose the desired input.
SET: press button to confirm.
730.138 | 08.1